Ceramic refractory panels are available in kit form for
the BDV series appliances
Appliance Model
Kit Name
33BDVT
AT1TBT
33BDVR
AT1CBB
36BDVT
BT2CBB
39BDVT
CT2CBB
43BDVT
DT2CBB
6. Place the rear refractory panel in place. Locate the
lower edge of the panel in the ledge formed by the
top of the rear log support bracket.
7. Slide the side refractory panels into place to hold
the rear panel secure. Adjust the top adjustable
tabs to hold the side panel against the firebox wall
and secure the tab. Repeat the procedure on the
other side.
8. Replace the logs and window frame assembly.
For aesthetic purposes we recommend lining up
the horizontal mortar lines.
Front Window Screen
Ceramic Refractory Kits
The fireplace, when installed, must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electric Code.
For USA installations follow the local
codes and the national electrical code
ANSI/NFPA No. 70.
Should this fan require servicing or
repair the power supply must be
disconnected. For rewiring of any
replacement parts refer to Figure 52.
Any electrical rewiring of this fan must
be done by a licensed electrician.
Wiring Instructions
Black
White
Ground
Speed
Control
Temperature
Sensor
Fan
FP1025
Fig. 52 FK24 fan wiring.
Take care when handling the refractory
panels as they are fragile until held in
place and supported.
Installation Refer to Figures 53 & 54
1. Remove the front window frame assembly.
2. Remove the logs.
3. Place the lower supports for the side refractory
panels on the base of the firebox. Place each
support so that the slotted hole fits over the forward
screw head along the edge of the base.
4. Lay the angular base panels in place on the floor of
the firebox on either side of the burner housing
assembly.
5. Loosely attach the top adjustable tabs to the studs
located in the top of the firebox toward the front
corners.
Adjustable
Tab
Side
Panel
Floor
Refractory
Panel
Lower Side Supports
Adjustable
Tab
Side
Panel
Floor
Refractory
Panel
Log Support
Burner Tray
Back Panel
FP1231
Fig. 53 Ceramic panel installation.
Rear
Refractory
Panel
Firebox Back
Panel
Rear Panel
Support
Brackets
Rear Log
Support
FP1233
Fig. 54 Rear refractory panel installation.
An optional front window screen is available for the
36BDV, 39BDV and 43BDV.
Appliance Model
Kit Name
36BDVT/36BDVR
BTISOB
39BDVT/39BDVR
CTISOB
43BDVT/43BDVR
DTISOB
Installation Refer to Figure 55
DO NOT ATTEMPT to install or remove
the screen while the appliance is hot.