15
70D0005
Damper Stop
Damper
TPB Gas Log Set
Figure 13 -
Damper Stop Installation.
FIREPLACE PREPARATION
BEFORE FULLY INSTALLING THE UNIT:
• Turn
OFF
the gas supply to the fireplace or firebox.
• Seal any fresh air vents and/or ash clean-out doors located on the floor or wall of the fireplace. If left
unsealed, drafting may cause pilot outage or sooting. Use a heat resistant sealant.
Do not seal the
chimney flue damper.
INSTALLING VENTED APPLICATIONS
Manual and milli-volt controlled gas logs may be installed as a vented decorative log set in compliance with
ANSI Z21.60 and National Fuel Gas Code, Section 6.6.
Since, the gas logs are operated with the damper
open, non-combustible material and minimum mantel requirements do not apply.
BEFORE INSTALLING THE APPLIANCE:
• Turn off gas supply to fireplace or firebox.
• Have the fireplace floor and chimney professionally cleaned to remove ashes, soot, creosote or other obstructions.
Have this cleaning performed annually after installation.
• Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot
outage or sooting. Use a heat-resistant seal-
ant.
Install and operate the appliance as directed in
this manual.
DAMPER STOP INSTALLATION:
A damper stop must be provided with the unit.
Contact your dealer to obtain one. The damper stop
must be installed as shown in
Figure 13
to prevent
full closure of the fireplace damper blade and pro-
vide a minimum 29 square inch flue opening.
W
ARNING
The fireplace and gas logs function as a system. If the fireplace is spilling into the
room (check with a match or a smoke stick), reposition the damper clamp until
a positive draft is obtained by opening the damper. If negative pressure in home
prevents having a positive draft, contact your dealer for assistance.
W
ARNING
W
ARNING
Before installing in a solid fuel burning
fireplace, The chimney flue and firebox must
be cleaned of soot, creosote, ashes and
loose paint by a qualified chimney cleaner.
This appliance is for installation only in a solid fuel burning fireplace (masonry
fireplace or manufactured fireplace) with a working flue and constructed of
noncombustible material.
Exception:
DO NOT install this appliance in a factory-built fireplace that includes
instructions stating that it has not been tested or should not be used with
unvented gas logs. This log set may be installed as a vented log set.