25
18NB/24NB Gas Log Set
81D0108
OPERATING INSTRUCTIONS - MILLIVOLT
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If
piezo ignitor does not light the pilot, refer to instructions for
Match lighting Instructions, Page 26.
4. Turn gas control knob clockwise
to the OFF position and turn ON/OFF switch to OFF position.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow the instructions under
What to Do If you Smell Gas, Page 24.
6. From OFF position, turn the gas control knob counterclockwise
to IGN position. Push in control
knob for 5 seconds.
NOTE: If you are running the heater for the first time, it may be neces-
sary to press in the control knob for 30 seconds or longer to allow air to bleed out of the gas
piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from
shutting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to
ON position.
11. If the gas logs will not operate, follow the instructions To Turn Off Gas To Heater below and call your
service technician or gas supplier.
Pilot
MILLIVOLT CONTROL LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO HEATER
1. Turn control knob clockwise
to OFF position to completely shut off the heater.
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
FP2274
NB burner
Controls
Pilot
Switch
Hi/Lo Knob
On/Off/Pilot Knob
Piezo Ignitor