Ref.  Description 

NV360 

NV580

 

6.  Ceramic Tile (single) 

57803 

57803

 

7.  Manifold Assembly 

10000765 

10000765

  8a.  Ceramic Hearth Panel (Left) 

20002274 

20002322

  8b.  Ceramic Hearth Panel (Right) 

20002275 

20002323

 

9.  Ceramic Panel (Rear) 

20002273 

20002319

  10a.  Ceramic Panel (Left Side) 

20002271 

20002321

  10b.  Ceramic Panel (Right Side) 

20002272 

20002320

  11.  Glass with Gasket 

20002205 

20002369

  12.  Gasket Glass 

10000992 

10000992

  13.  Door Frame Assembly 

20003710 

20003711

  14.  Clamp Frame Window 

54174 

54174

  15.  Trim Frame Window (Pb) (w/two magnets) 

57483 

20002072

  16.  Louvre Assembly Top 

10000039 

20002380

  17.  Bottom Louvre Assy. 

10000040 

20002381

  18.  Bottom Louvre Hinge 

52356 

52356

  19.  Deflector Top 

54364 

20002286

  20.  Grate Assembly 

20002196 

20002442

  21a.  Orifice - Front Burner - LP 

20003872 

20002540

  21b.  Orifice - Front Burner - Natural 

53349 

20002150

  21c.  Orifice - Rear Burner - LP 

20002385 

10000616

  21d.  Orifice - Rear Burner - Natural 

20002498 

20003611

  22.  Switch ON/OFF 

51842 

51842

  23a.  Valve - Honeywell VS8421 - Natural 

10001782 

10001782

  23b.  Valve - Honeywell VS8421 - LP 

10001759 

10001759

  24a.  Valve - SIT 820 - Natural 

52677 

52677

  24b.  Valve - SIT 820 - LP 

52678 

52678

  25a.  Pilot Assembly - Natural 

10002264 

10002264

  25b.  Pilot Assembly - LP 

10002265 

10002265

  26.  Electrode Ignitor w/cable SIT24 

10001297 

10001297

  27.  Sensing Electrode w/cable 

57885 

57885

  28.  Pilot Tube 1/8" x 24" Long w/fittings 

10001296 

10001296

  29.  Thermocouple 24" 

53373 

53373

  31.  Thermopile 18" RS 

51827 

51827

  32.  Pilot Top Convertible 

10002266 

10002266

  33.  Hood Pilot 3 Way 

10002385 

10002385

  34a.  Pilot Orifice #65 - Natural 

10002268 

10002268

  34b.  Pilot Orifice #35 - LP 

10002269 

10002269

  35.  Ignitor Piezo (SIT Valve) 

52464 

52464

  36a.  Air Shutter - Front - LP 

20000680 

20000680

  36b.  Air Shutter - Rear - LP 

20000184 

20000680

  37.  Air Shutter - Natural 

20000129 

20000129

  38.  Fan w/Bracket 

54103 

54103

  39.  Electrical Cord (6 ft.) 

51865 

51865

  40.  Fan Temp. Sensor 

51704 

51704

  41.  Speed Control 

51738 

51738

  42.  Speed Control Knob 

51882 

51882

  43.  Remote Switch Kit (not shown) 

53875 

53875

Summary of Contents for NV360 Series

Page 1: ...e must be per formed by a quali ed installer service agency or the gas supplier What to do if you smell gas Do not try to light any appliance Do not touch any electric switch do not use any phone in y...

Page 2: ...as Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Gas Line Installation 6 Remote Switch Installation 7 Alternate Switch Location 7 EB 1 Electrical Box 7 Install the Venting System Fl...

Page 3: ...d not be used as a drying rack for clothing nor should Christmas stock ings or decorations be hung in the area of it 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be...

Page 4: ...mm 47 1194 mm B 37 953 mm 41 1048 mm C 36 914 mm 42 1067 mm D 24 622 mm 28 724 mm E 7 179 mm 7 179 mm F 6 152 mm 6 152 mm G 1 32 mm 1 32 mm H 19 489 mm 23 591 mm I 5 140 mm 5 140 mm J 25 641 mm 31 79...

Page 5: ...G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Fig 2b Combustible mantel leg minimum installation CFM170 DV Builder Front View O N M L K J F G H I Mantel Le...

Page 6: ...con rm the nal depth Finishing Noncombustible materials such as brick and tile can be extended over the face of the unit Do not cover the glass door or grille If a trim kit is to be installed brick an...

Page 7: ...4 9 WIRING DIAGRAM 1 8 99 djt 11 9 99 added thermopile Thermopile W584 9 Fig 5 Remote switch wiring diagram for R models FP1024 alternate remote switch location 1 27 00 djt FP1024 Fig 6 Alternate swit...

Page 8: ...er frame NOTE A restop is not required at the roof Fig 8 Firestop draftstop positions FP384 FIRESTOP 11 21 96 adapted from IGF53 FP384 Attic Installation Firestop position when area above ceiling is a...

Page 9: ...in height Up to an 8 ft horizontal vent run can be installed within the vent system using a maximum of two 2 90 degree elbows or four 4 45 degree elbows B Vertical installations up to 40 feet 12m in...

Page 10: ...monia household cleaner and warm water gas replace glass cleaner is recommended After initial use the glass should be cleaned two or three times during each heating season depending on the circumstanc...

Page 11: ...logs by placing a small piece of wool on your ngertip and pushing it onto the log Do not place ember material in the inside corners of the front logs Lava Rock The lava rock provided with this replace...

Page 12: ...n and bathroom 2 Light unit and operate for 5 minutes 3 Hold an ignited match cigarette or smoke match in front of the unit Refer to Figure 17 for location of the draft hood opening 4 Check to make su...

Page 13: ...down the main burner assembly The sensor is located above the rebox behind the top louvre assembly It is accessible by removing the top louvre assembly CAUTION The rebox Vent Safety Switch sensor and...

Page 14: ...HITE WHITE WHITE WHITE WHITE WHITE BLACK FP670 NOVA SIT 822 VALVE WIRING DGRM w Honeywell S8600 B Ignition Module 4 30 98 PILOT H I L O H I LO E A P I L O T 1 5 3 4 GREEN MV MVPV PV GND BURNER 24V GND...

Page 15: ...all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not t...

Page 16: ...height All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Pilot Lights with Piezo Ignitor YE...

Page 17: ...le oper ates the main valve operation ON and OFF Clean and or adjust maximum ame impingement on thermopile and thermocouple Turn valve knob to PILOT Maintain ow to pilot millivolt meter should read gr...

Page 18: ...crews A pressure regulator tower B and the spring and diaphragm assembly C Fig 22 FC107 SIT820 valve conversion 10 03 A B C OFF P I L O T O N FC107 Fig 22 Remove mounting screws pressure regulator tow...

Page 19: ...Burner Pan NV580 CO110 Front View Top View Front View Fig 27 Install conversion air shutters NOTE It is not necessary to remove the pilot tube for conversion 7 Remove pilot hood by lifting up Fig 28 8...

Page 20: ...alve Most of these components may require only an oc casional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a quali ed technician Logs May Be H...

Page 21: ...e Log Top Right B29 E7 1f Log Top Center Left E5 1g Log Top Center Right E6 2 Volcanic Rock 20000376 20000376 3 Ember Package 51915 51915 4 Lava Rock Burner 57897 57897 5a Burner Housing Assembly Natu...

Page 22: ...000616 21d Ori ce Rear Burner Natural 20002498 20003611 22 Switch ON OFF 51842 51842 23a Valve Honeywell VS8421 Natural 10001782 10001782 23b Valve Honeywell VS8421 LP 10001759 10001759 24a Valve SIT...

Page 23: ...ell Valve not shown 20000062 20000062 45 Vent Safety Switch 10002013 10002013 46a Regulator Head Natural 10001006 10001006 46b Regulator Head LP 10001007 10001007 Fuel Conversion Kits Conversion Kit N...

Page 24: ...eed control can be installed in an electrical box at normal wall switch height for conve nient access 4 The power supply may be connected in 2 ways Method A Route the 6 1 8m lead tted to the unit to a...

Page 25: ...H102 rear ceramic support 2 23 99 djt Rear Ceramic Panel Back of Firebox Burner Rear Log Support H102 Fig 37 Rear ceramic panel placement Decorative Frame Trims A selection of decorative frame trim ki...

Page 26: ...26 NV360 580 Series 20003565...

Page 27: ...tion the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this...

Page 28: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: