background image

10

NV360/580 Series 

20003565

Operating Instructions

Glass Information

Only glass approved by CFM Corporation 
should be used on this fireplace.

• 

The use of any non-approved replacement glass will 
void all product warranties.

• 

Care must be taken to avoid breakage of the glass.

• 

Do not operate appliance with glass front 
removed, cracked or broken.

• 

Replacement glass (complete with gasket) is 
available through your Majestic Fireplaces 
dealer and should only be installed by a licensed 
qualified service person.

Louvre Removal

To remove the 
louvre assembly 
top, pull louvre up, 
then lift out. (Fig. 9) 
The bottom louvre 
assembly is hinged at 
the bottom edge and 
swings down.

Glass Cleaning

It will be necessary to clean the glass periodically. 
During start-up, condensation, which is normal, forms 
on the inside of the glass and  causes lint, dust and 
other airborne particles to cling to the glass surface. 
Also, initial paint curing may deposit a slight film on 
the glass. It is therefore recommended the glass 
be cleaned two or three times with a non-ammonia 
household cleaner and warm water (gas fireplace 
glass cleaner is recommended). After initial use the 
glass should be  cleaned two or three times during 
each heating season depending on the circumstances 
present.

Clean glass after first two weeks of 
operation.
Do not clean glas when hot.
Do not use abrasive cleaners.
Do not strike or slam the glass.

1.

2.

FP444

remove louvre

12/99

Louvre 

Assembly 

Top

Glass Panel

FP444

Fig. 9

  Remove louvre assembly 

top.

Window Frame Assembly Removal

1.  Shut off gas.
2.  Allow the fireplace to cool if it has been operating.
3.  Remove louvre assembly top. (Refer to Louvre Re-

moval, Fig. 9)

4.  Open the bottom louvre assembly.
5.  Release the two (2) clamps at the bottom of the win-

dow frame by pulling down on the clamp handles.

6.  Lift off the window frame assembly as shown. (Fig. 

10)

7.  To reinstall window frame assembly, follow the above 

procedure in reverse.

FP771a

DV360/580

GLASS REMOVAL-CLIP

1/27/00   djt

Clamps

Glass Frame

Fireplace 
Front

Glass 

Panel

Glass 

Panel

Pull Clamp 

Hook

Push Clamp 

Handle

FP771a

Fig. 10

  Glass panel removal.

Log Installation

 

Logs 

NV360 

NV580

  Log Front Left 

B25 

E1

  Log Front Right 

B26 

E2

  Log Rear 

B27 

E3

  Log Top Left 

B28 

E4

  Log Top Center Left 

-- 

E5

  Log Top Center Right 

-- 

E6

  Log Top Right 

B29 

E7

Summary of Contents for NV360 Series

Page 1: ...e must be per formed by a quali ed installer service agency or the gas supplier What to do if you smell gas Do not try to light any appliance Do not touch any electric switch do not use any phone in y...

Page 2: ...as Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Gas Line Installation 6 Remote Switch Installation 7 Alternate Switch Location 7 EB 1 Electrical Box 7 Install the Venting System Fl...

Page 3: ...d not be used as a drying rack for clothing nor should Christmas stock ings or decorations be hung in the area of it 9 Under no circumstances should any solid fuels wood coal paper or cardboard etc be...

Page 4: ...mm 47 1194 mm B 37 953 mm 41 1048 mm C 36 914 mm 42 1067 mm D 24 622 mm 28 724 mm E 7 179 mm 7 179 mm F 6 152 mm 6 152 mm G 1 32 mm 1 32 mm H 19 489 mm 23 591 mm I 5 140 mm 5 140 mm J 25 641 mm 31 79...

Page 5: ...G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Fig 2b Combustible mantel leg minimum installation CFM170 DV Builder Front View O N M L K J F G H I Mantel Le...

Page 6: ...con rm the nal depth Finishing Noncombustible materials such as brick and tile can be extended over the face of the unit Do not cover the glass door or grille If a trim kit is to be installed brick an...

Page 7: ...4 9 WIRING DIAGRAM 1 8 99 djt 11 9 99 added thermopile Thermopile W584 9 Fig 5 Remote switch wiring diagram for R models FP1024 alternate remote switch location 1 27 00 djt FP1024 Fig 6 Alternate swit...

Page 8: ...er frame NOTE A restop is not required at the roof Fig 8 Firestop draftstop positions FP384 FIRESTOP 11 21 96 adapted from IGF53 FP384 Attic Installation Firestop position when area above ceiling is a...

Page 9: ...in height Up to an 8 ft horizontal vent run can be installed within the vent system using a maximum of two 2 90 degree elbows or four 4 45 degree elbows B Vertical installations up to 40 feet 12m in...

Page 10: ...monia household cleaner and warm water gas replace glass cleaner is recommended After initial use the glass should be cleaned two or three times during each heating season depending on the circumstanc...

Page 11: ...logs by placing a small piece of wool on your ngertip and pushing it onto the log Do not place ember material in the inside corners of the front logs Lava Rock The lava rock provided with this replace...

Page 12: ...n and bathroom 2 Light unit and operate for 5 minutes 3 Hold an ignited match cigarette or smoke match in front of the unit Refer to Figure 17 for location of the draft hood opening 4 Check to make su...

Page 13: ...down the main burner assembly The sensor is located above the rebox behind the top louvre assembly It is accessible by removing the top louvre assembly CAUTION The rebox Vent Safety Switch sensor and...

Page 14: ...HITE WHITE WHITE WHITE WHITE WHITE BLACK FP670 NOVA SIT 822 VALVE WIRING DGRM w Honeywell S8600 B Ignition Module 4 30 98 PILOT H I L O H I LO E A P I L O T 1 5 3 4 GREEN MV MVPV PV GND BURNER 24V GND...

Page 15: ...all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not t...

Page 16: ...height All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Pilot Lights with Piezo Ignitor YE...

Page 17: ...le oper ates the main valve operation ON and OFF Clean and or adjust maximum ame impingement on thermopile and thermocouple Turn valve knob to PILOT Maintain ow to pilot millivolt meter should read gr...

Page 18: ...crews A pressure regulator tower B and the spring and diaphragm assembly C Fig 22 FC107 SIT820 valve conversion 10 03 A B C OFF P I L O T O N FC107 Fig 22 Remove mounting screws pressure regulator tow...

Page 19: ...Burner Pan NV580 CO110 Front View Top View Front View Fig 27 Install conversion air shutters NOTE It is not necessary to remove the pilot tube for conversion 7 Remove pilot hood by lifting up Fig 28 8...

Page 20: ...alve Most of these components may require only an oc casional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a quali ed technician Logs May Be H...

Page 21: ...e Log Top Right B29 E7 1f Log Top Center Left E5 1g Log Top Center Right E6 2 Volcanic Rock 20000376 20000376 3 Ember Package 51915 51915 4 Lava Rock Burner 57897 57897 5a Burner Housing Assembly Natu...

Page 22: ...000616 21d Ori ce Rear Burner Natural 20002498 20003611 22 Switch ON OFF 51842 51842 23a Valve Honeywell VS8421 Natural 10001782 10001782 23b Valve Honeywell VS8421 LP 10001759 10001759 24a Valve SIT...

Page 23: ...ell Valve not shown 20000062 20000062 45 Vent Safety Switch 10002013 10002013 46a Regulator Head Natural 10001006 10001006 46b Regulator Head LP 10001007 10001007 Fuel Conversion Kits Conversion Kit N...

Page 24: ...eed control can be installed in an electrical box at normal wall switch height for conve nient access 4 The power supply may be connected in 2 ways Method A Route the 6 1 8m lead tted to the unit to a...

Page 25: ...H102 rear ceramic support 2 23 99 djt Rear Ceramic Panel Back of Firebox Burner Rear Log Support H102 Fig 37 Rear ceramic panel placement Decorative Frame Trims A selection of decorative frame trim ki...

Page 26: ...26 NV360 580 Series 20003565...

Page 27: ...tion the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this...

Page 28: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: