63
Remarks:
1. In heating mode, if the water out temperature is higher than the set temperature over 7
℃
, LED controller displays
EE04 for water over-heating protection.
2. In cooling mode, if the water out temperature is lower than the set temperature over 7
℃
, LED controller displays
PP11 for water over-cooling protection.
For example below:
Mode
Water out
temperature
Setting
temperature
Condition
Malfunction
Heating mode
36
℃
29
℃
Tout - Tset
≧
7
℃
EE04
Over heating protection for water
temperature (T2)
Cooling mode
23
℃
30
℃
Tset - Tout
≧
7
℃
PP11
Too low protection for water
temperature (T2)
T
SET Temp.
+7
℃
T
SET Temp.
+5
℃
Frequency Decrease
EE04 Water Heating Protection
PP11 Water Cooling Protection
护
Compressor Stop and EE04 displays
T
water out
(
℃
)
Normal Operation
T
water out
(
℃
)
T
SET Temp.
-7
℃
T
SET Temp.
-5
℃
Normal Operation
Frequency Decrease
Compressor Stop and PP11 displays
Summary of Contents for 7008470M
Page 2: ......
Page 4: ...2 SCHWIMMBAD WÄRMEPUMPE Benutzer und Wartungshandbuch LUXURYBLACK INVERTER ...
Page 8: ...6 2 Abmessung LuxuryBlack i14 LuxuryBlack i16 ...
Page 9: ...7 LuxuryBlack i20 ...
Page 10: ...8 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 34: ...32 9 Explosionszeichnung Explosionszeichnung LuxuryBlack i14 LuxuryBlack i16 ...
Page 36: ...34 LuxuryBlack i20 ...
Page 38: ...36 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 43: ...41 Swimming Pool Heat Pump User and Service Manual LUXURYBLACK INVERTER ...
Page 47: ...45 2 Dimension LuxuryBlack i14 LuxuryBlack i16 ...
Page 48: ...46 LuxuryBlack i20 ...
Page 49: ...47 LuxuryBlack iV26 LuxuryBlack iV30 Unit mm ...
Page 67: ...65 7 Electrical Wiring LuxuryBlack i14 LuxuryBlack i16 LuxuryBlack i20 ...
Page 68: ...66 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 70: ...68 9 Exploded view LuxuryBlack i14 LuxuryBlack i16 ...
Page 72: ...70 LuxuryBlack i20 ...
Page 74: ...72 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 79: ...77 ...
Page 82: ...80 2 3 The main interface ...
Page 88: ...86 ...
Page 89: ...87 A0155PXI01 ...