61
4. Compressor or driver board
damaged
VDC voltage too low protection
EE12
1.
Mother line voltage is too low
2. Driver board is damaged.
1. Check if the power is in the normal
range
2. Change driver board
Input current over high protection.
EE13
1.
The compressor current is too
large momentary
2.
The water flow is abnormal
3.
Power fluctuations within a short
time
4. Wrong PFC inductor
1.
Check the compressor
2.
Check the waterway system
3.
Check if the power is in the normal
range
4. Check if the correct PFC inductor is
used
IPM module thermal circuit is
abnormal
EE14
1.
Output enormity of IPM module
thermal circuit
2.
Fan motor is abnormal or damaged
Fan blade is broken
1.
Change a driver board
2.
Check if the motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
IPM module temperature too high
protection
EE15
1.
Output exception of IPM module
thermal circuit
2.
Motor is abnormal or damaged
3. Fan blade is broken
1.
Change a driver board
2.
Check if the fan motor speed is too
low or fan motor damaged, change
another one
3. Change another fan blade
PFC module protection
EE16
1.
Output exception of PFC module
2.
Motor is abnormal or damaged
3.
Fan blade is broken
4. Input voltage leap, input power is
abnormal
1.
Change a driver board
2.
Check if the motor speed is too
low or fan motor damaged, change
another one
3.
Change another fan blade
4. Check the input voltage
DC fan motor failure
EE17
1.
DC motor is damaged
2.
Main board is damaged
3. The fan blade is stuck
1.
Detect DC motor, replace with a
new one
2.
Change a new main board
3. Find out the barrier and work it
out
PFC module thermal circuit is
abnormal
EE18
The driver board is damaged
1.
Change a new driver board
2. Check if the fan motor speed is too
low or fan motor damaged, change
another one
PFC module high temperature
protection
EE19
1.
PFC module thermal circuit output
abnormal
2.
Motor is abnormal or damaged
3.
Fan blade is broken
4. The screw in the driver board is not
tight
1.
Change a new driver board
2.
Check if the motor speed is too
low or fan motor damaged, change
another one
3.
Change another fan blade
4. Check if the screw is loose
Input power failure
EE20
The supply voltage fluctuates too
much
Check whether the voltage is stable
Summary of Contents for 7008470M
Page 2: ......
Page 4: ...2 SCHWIMMBAD WÄRMEPUMPE Benutzer und Wartungshandbuch LUXURYBLACK INVERTER ...
Page 8: ...6 2 Abmessung LuxuryBlack i14 LuxuryBlack i16 ...
Page 9: ...7 LuxuryBlack i20 ...
Page 10: ...8 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 34: ...32 9 Explosionszeichnung Explosionszeichnung LuxuryBlack i14 LuxuryBlack i16 ...
Page 36: ...34 LuxuryBlack i20 ...
Page 38: ...36 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 43: ...41 Swimming Pool Heat Pump User and Service Manual LUXURYBLACK INVERTER ...
Page 47: ...45 2 Dimension LuxuryBlack i14 LuxuryBlack i16 ...
Page 48: ...46 LuxuryBlack i20 ...
Page 49: ...47 LuxuryBlack iV26 LuxuryBlack iV30 Unit mm ...
Page 67: ...65 7 Electrical Wiring LuxuryBlack i14 LuxuryBlack i16 LuxuryBlack i20 ...
Page 68: ...66 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 70: ...68 9 Exploded view LuxuryBlack i14 LuxuryBlack i16 ...
Page 72: ...70 LuxuryBlack i20 ...
Page 74: ...72 LuxuryBlack iV26 LuxuryBlack iV30 ...
Page 79: ...77 ...
Page 82: ...80 2 3 The main interface ...
Page 88: ...86 ...
Page 89: ...87 A0155PXI01 ...