MP1800 Router Install Manual V1
.2
2400 1250
4800 625
9600 312
19200 156
38400 78
56000 60
64000 50
2048000 30
Note
When adopting EIA/TIA-232 cable, BR rate should not be over 64Kbps in
syn mode.
C o n n e c t 1 S A E M o d u l e I n t e r f a c e C a b l e
Connect the cables of syn/asyn serial port module as follows:
Step 1: Insert one side of DB-25 to the DB-25-interface of the 1SAE
module and then screw down fixed knob to fix the cable on the DB-25-
interface of the 1SAE module.
Step 2: Connect another DB25 interface to V.24-V.35 (DB-25, M-34)
cable and then connect to the following equipment:
1.
If WAN is DDN line, connect (V.35 cable) to digital Modem V.35
interface.
2.
If WAN is dialup line, connect (V.24 cable) to analog Modem serial
port.
Note
When connecting, pay attention to the ID on the interface, avoiding
inserting into other interface and damaging the module or router host.
Connect 1CE1/1E1 Module Interface
Cable
Connect 1CE1/E1 interface according to the following steps:
Step 1: Connect one side of BNC plug to the BNC interface of 1CE1/E1
module.
Step 2: Connect another side to the equipment.
Maipu Confidential & Proprietary Information
Page
47
of
55