background image

MP1800 Router Install Manual V1

.2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install USIM Card 

USIM card is used to store the accounting information. The USIM card is 
purchased by the user. The metal face of the USIM card is adown. Refer to 
the appearance diagram of the cassette, Plug and Play. 

SM1 Module 

The RM2-SM1 module is used to encrypt and de-encrypt. The panel of the 
RM2-SM1 module does not have external interface. 
 

RM2-SM1 Module Appearance 

The appearance of the RM2-SM1 interface module is as follows: 

 

RM2-SM1 panel diagram 

The indicators of the RM2-SM1 module: 

ACT 

On: Some data is encrypted or de-encrypted; 
Off: Idle 

RDY 

On: The card is available, that is, RDY and ENABLE are valid at the same time; 
Off: The card is unavailable; 
Flash: The card is RDY, but the host does not enable. 

 

 Maipu Confidential & Proprietary Information 

     Page 

31 

of 

55 

 
 

Summary of Contents for MP1800

Page 1: ...gy Co Ltd No 16 Jiuxing Avenue Hi tech Park Chengdu Sichuan Province People s Republic of China 610041 Tel 86 28 85148850 85148041 Fax 86 28 85148948 85148139 URL http www maipu com Email overseas mai...

Page 2: ...r any specific purpose Further Maipu reserves the right to revise this document and to make changes from time to time in its content without being obligated to notify any person of such revisions or c...

Page 3: ...ccessibility Contents index headings numbering Good Fair Average Poor Evaluate this document Editorial Language vocabulary readability clarity technical accuracy content Good Fair Average Poor Your su...

Page 4: ...t Channelized E1 Module 1CE1 17 Non channelized E1 E1 Series 18 1 port Non channelized E1 Module 1E1 18 IP Phone Module VOP VOS Series 19 IP Phone Module of 1 port IP Phone 1VOP 19 IP Phone Module of...

Page 5: ...st Cables 42 Connect Protection Ground Wire 43 Connect Power Supply 43 Module Installation 45 Connect 1SAE Interface Cable 45 Connect 1CE1 1E1 Module Interface Cable 47 Connect 1VOP 2VOP Module Interf...

Page 6: ...e mechanism of various access combinations Product Features z Wired and wireless integration supporting 3G and WLAN access and inter connecting with the wired network seamlessly z Routing and switchin...

Page 7: ...ures MP1800 Series Multi service Router Appearance MP1800 multi service access router Front and Back Panels of MP1800 Series Multi service Router Front and back panels of RM1800 21 AC router Maipu Con...

Page 8: ...ront and back panels of RM1800 22 AC router Front and back panels of RM1800 23 AC router Front and back panels of RM1800 31 AC router Front and back panels of RM1800 31W AC router Maipu Confidential P...

Page 9: ...nt and back panels of RM1800 31W DC48 router Front and back panels of RM1800 35 AC router Front and back panels of RM1800 35W AC router Front and back panels of RM1800 36W AC router Maipu Confidential...

Page 10: ...le port FE0 WAN Ethernet 0 z 100M data rate indicator of 10 100M Ethernet port on for 100M and off for 10M z LINK ACT Ethernet port connection data receiving and sending indicator FE1 WAN Ethernet 1 z...

Page 11: ...100M Ethernet electric port RM1800 21 AC LAN port RJ45 Four 100M Ethernet electric ports CONSOLE RJ45 Console port WAN port RJ45 Two 100M Ethernet electric ports LAN port RJ45 Four 100M Ethernet elect...

Page 12: ...C USB port USB interface One USB interface The interfaces on the back panel of the MP1800 series router Interface Interface Type Description Corresponding slot ON OFF The power switch ON or OFF AC 100...

Page 13: ...hree high speed multi function slots USB high speed interface One except for RM1800 21 AC Processor High speed RISC processor FLASH 32Mbyte SDRAM 256Mbyte RM1800 21 AC RM1800 22 AC RM1800 23 AC RM1800...

Page 14: ...odules are suitable for slot 1 RM2 1ADSL and xGSHDSL modules are suitable for slot 2 but when the modules are inserted WAN1 FE1 on the front panel is unavailable The 3G module of RM2 is suitable for s...

Page 15: ...ther devices that use 2 4G frequency band will cause interference for WLAN In serious case WLAN cannot be used The 2 4G frequency band devices include Bluetooth device microwave oven digital wireless...

Page 16: ...mpletes 1 port sync async serial data flow receiving sending and processing The port operates in synchronous mode DCE mode 2 048Mbps DTE mode 8 Mbps The port in asynchronous mode operates 115 2Kbps Th...

Page 17: ...e bps 1200 1200 300 Maximum baud rate bps 128K 8M 115 2K Dialup Backup Supported protocol service X25 HDLC PPP SLIP FR LAPB HDLC PPP SLIP Channelized E1 Module CE1 1 port Channelized E1 Module 1CE1 Th...

Page 18: ...er 1 group Interface standard G 703 Supported protocol PPP X 25 HDLC FR Non channelized E1 E1 Series 1 port Non channelized E1 Module 1E1 The 1 port non channelized E1 module provides a data transmiss...

Page 19: ...1 interface attributes Attributes Description Interface BNC RJ45 cannot be used together Interface number 1 group Interface standard G 703 Supported service X 25 FR Supported protocol PPP HDLC IP Phon...

Page 20: ...able and RJ11 phone wire 1VOP Interface Attributes 1 port IP phone module 1VOP interface attributes Attributes Description Interface RJ45 jack Interface number 1 Supported protocol H 225 H 245 RTP RTC...

Page 21: ...le 2VOP Interface Attributes 2 port IP phone module 2VOP interface attributes Attributes Description Interface RJ45 jack two RJ11 plugs Interface quantity 2 RJ11 Supported protocols H 225 H 245 RTP G...

Page 22: ...le The cables of the 1VOS module are RJ45 4 5 signal cable and RJ11 phone wire 1VOS Interface Attributes The 1 port switch IP phone module 1VOS interface attributes Attribute Description Interface RJ4...

Page 23: ...face Attributes 2 port switch IP phone module 2VOS interface attributes Attributes Description Interface RJ45 jack two RJ11 plugs Interface quantity 2 RJ11 Supported protocols H 225 H 245 RTP G 711 G...

Page 24: ...l B2 that is rate is B2 64K or B1 B2 128K Cables of 1STA Interface Module The 1STA cable is the RJ45 direct connected cable 1STA Module Interface Attributes The interface attributes of the 1STA module...

Page 25: ...e standard RS 232 Min baud rate bps 300 Max baud rate bps 115 2K Supported services Connecting terminals with the terminal number fixing function Connecting ATM Connecting PC workstation Connecting ro...

Page 26: ...hat the interface has data sent and received G SHDSL Series Module 2 port G SHDSL RM2 2SHDSLmodule is used by MP1800 series multi service access router realizing 2 port access Internet via one RJ45 in...

Page 27: ...face attributes of the G SHDSL module Attribute Description Interface RJ45 jack Interface quantity 2 or 4 Supported protocols ITU G hs ITU T G 994 1 ITU G shdsl ITU T G 991 2 ITU G shdls bis ITU T G 9...

Page 28: ...t are one FXO port and one FXS port 4S1O Module Interface Attributes The interface attributes of the 4S1O module Attribute Description Interface RJ45 jack Interface quantity 5 Supported protocols H 22...

Page 29: ...e 1xRTT Green On with 1xRTT service Off no EVDO service EVDO Green On with EVDO service RM2 3G GSM RM2 3G GSM module needs to insert the WCDMA 3G module and USIM card The appearance of the RM2 3G GSM...

Page 30: ...sert the TD SCDMA 3G module and USIM card The appearance of the RM2 3G TD interface module RM2 3G TD panel The meanings of the indicators on RM2 3G TD module Off power off WWAN Green On power on Off w...

Page 31: ...and de encrypt The panel of the RM2 SM1 module does not have external interface RM2 SM1 Module Appearance The appearance of the RM2 SM1 interface module is as follows RM2 SM1 panel diagram The indica...

Page 32: ...ctly especially do not connect phone lines including ISDN lines to serial ports z Pay attention to the laser use security for example do not keep eyes open at the optical emitting mouth of LASER or th...

Page 33: ...reliability of the router reduces greatly The long time high temperature affects the life and speeds up the aging of insulation materials The recommended temperature and humidity in computer room Tem...

Page 34: ...s The specific limitations are as follows Gas Maximum value mg m3 SO 2 0 2 H 2 S 0 006 NH3 0 05 Cl 2 0 01 Anti static MP1800 router takes lots of measures in anti static but when the static exceeds a...

Page 35: ...ings and the distance between them had better be as long as possible z Be away from the strong power radio transmitters radar transmitter and high frequency high current equipments z Take electromagne...

Page 36: ...ck whether the router and the accessories are complete according to the purchase order Tools Equipment Tools z Slotted point screwdriver cross point screwdriver z Level ruler or tapeline z Anti static...

Page 37: ...int screwdriver level ruler or tapeline and anti static equipment Cabinet Installation Check Cabinet After MP1800 router is configured with the private brackets it can be installed and fixed normally...

Page 38: ...e the standard accessories Different cabinets have different dimensions and shapes Therefore to add cabinet accessories contact the supplier of the cabinet to provide genuine accessories The device mu...

Page 39: ...ts are met open the package and check whether the router and the accessories are complete according to the purchase order If there is some missing or damaged items in the package contact the equipment...

Page 40: ...of the cabinet face the operator Use two hands to hold the device stably and make the device keep horizontal Place the device on the pallet or trays from the front of the cabinet When placing the dev...

Page 41: ...device when installing the device in the cabinet it is recommended to reserve the 1U height between the devices Install the configured baffle of the cabinet between the devices Install Device on Desk...

Page 42: ...h of the hole drilled on the wall should be larger than the depth of the plastic expansion screw The recommended external diameter of the screw is 4mm Connect Host Cables This section describes how to...

Page 43: ...the AC noise filter whose center is directly connected to the chassis We call it chassis ground that is protection ground The chassis ground should be well grounded so as to make the induction power...

Page 44: ...Users should ensure the reliable grounding and make the corresponding processing The input wire of the DC power is the private three core DC wire Use the fork lug to connect the American standard DC t...

Page 45: ...y switch to ON Step 3 Check whether the power supply indicator of the front panel is on If not repeat step 1 and 2 Note If the power supply indicator is not on after repeating the above steps contact...

Page 46: ...f the device connected to the router is DTE or DCE refers to the MP1800 manuals Typical DTE and DCE devices Device Type Interface Type Typical Device DTE Pin type PC Router DCE Hole type MODEM Multipl...

Page 47: ...nnect another DB25 interface to V 24 V 35 DB 25 M 34 cable and then connect to the following equipment 1 If WAN is DDN line connect V 35 cable to digital Modem V 35 interface 2 If WAN is dialup line c...

Page 48: ...nsparent 2M mode in non transparent 2M mode LOS is on when not finding the frame synchronous signal and then becomes off after synchronization Connect 1VOP 2VOP Module Interface Cable Connect the cabl...

Page 49: ...the 1ST module as follows Step 1 Insert the RJ45 plug of the 1ST module interface cable to the RJ45 jack Step 2 Connect the other side of the interface cable to the corresponding device wire Connect...

Page 50: ...corresponding device Connect 4S1O Module Interface Cable Step 1 Connect the RJ11 plug of the 4S1O module interface cable to the RJ11 jack Step 2 Connect the other side of the RJ11 plug to the telepho...

Page 51: ...r receiving and sending signals The connection relation of RJ45 straight through cable type 5 twisted pair RJ45 Signal Direction RJ45 Description Length 1 TX0 1 2 TX0 2 Twisted pair 1 3 RX0 3 6 RX0 6...

Page 52: ...the LC interface Console Port Cable MP1800 console port cable is connected with PC 9 core serial jack and it is 8 core non screen cable One side is RJ45 plug and another is DB9 hole RJ45 jack Standar...

Page 53: ...ine The sequence relation of the input and output ports Input Port Cable Color Output Port 1 Black 1 4 Yellow 2 FXO 2 Red 1 LINE 3 Green 2 FXS The picture of the distribution box 4S1O Interface Cable...

Page 54: ...e lines with labels The corresponding relation is 1 2 3 6 4 5 7 8 Cable Twisted pair CAT 5E 8 core every two are twisted the external diameter is 6mm the cable sheath is black green The sequence and l...

Page 55: ...MP1800 Router Install Manual V1 2 The pin order of RJ 45 crystal head Maipu Confidential Proprietary Information Page 55 of 55...

Reviews: