MAINS S.C. E.M.Wosińscy Brzeziny 95-060 ul. Słowackiego 12, tel/fax: 48 46 8752 777 www.mains.pl; [email protected]
controller: Mv4k
Additional security features
14
MAINS S.C. E.M.Wosińscy Brzeziny 95-060 ul. Słowackiego 12, tel/fax: 48 46 8752 777 www.mains.pl; [email protected]
The operations of the motor elevation cover sensor (optional)
In situations where the controller is switched on, (the motors are working or not), and from any cause the motor elevation cover sensor
will be switched on, the motor will be stopped immediately and the work permit function will be turn off too.
This is indicated by an intermittent tone and flashing of the SERVICE LED on the front cover.
One should then use the safety switch STOP [4] or turn the controller off the power with the use of switch POWER [5],
and remove the cause of switching on the sensor.
Additional security features for user:
WARNING!
The condition of re-enabling the work permit
function is to switch off the controller from the grid
and to make sure that the cause of its activation
was removed and switching on the power is
safe for the cashier counter users and the surrounding.
S. START
POWER
POWER
SERVICE
Mv4k
O
T P
S
CTRL
OUT
2
Digital programmable belt controller
S. START
POWER
POWER
SERVICE
Mv4k
O
T P
S
CTRL
OUT
2
Digital programmable belt controller