B Operating Instructions for Rotary Joints Series DX/DXS
6
.
Mounting
18/27
© 2011 by Christian Maier GmbH & Co. KG Maschinenfabrik
This document may not be copied or disclosed to third parties.
All rights, including copyright and property rights, reserved by Maier.
AB-DX_en – Version 08 – 01.03.2011
B
6.2
Connecting the rotary joint
WARNING
For safety reasons, always provide an anti-rotation system.
INFORMATION
Also refer to chapter 5. for important information on this section.
B-20
1.
Mount anti-rotation device [2] of the rotary joint
housing [1].
The information on the admissible mounting
position of the rotary joint provided in the sec-
tion "Specifications and Spare Parts" must be
adhered to.
2.
Mount torque monitoring system [3] or, as an
alternative, a vibration pick-up to the anti-
rotation device.
3.
Connect the housing [4].
4.
See the following sections for information on
the correct design of the connection line.
General information on connection lines
The following sections show examples of the design of the flexible connection elements:
permissible movement (go for)
impermissible movement (avoid)