INSTRUCTION MANUAL FOR DISHWASHERS
Page 7 of 12
GB
4.6
Discharging the Appliance
4.6.1 Models without discharging pump
1. Turn off the appliance as described in the “Turning off
the Appliance” paragraph, above.
2. Remove the overflow cap: wait until the tank is
completely empty.
4.6.2 Models with discharging pump
1. Turn off the appliance as described in the “Turning off
the Appliance” paragraph, above.
2. Remove the overflow cap and shut the door.
3. Push the “discharging pump” button shown to drain.
START
4. On models without the “discharging pump button”, turn
off the appliance as described in the “Turning off the
Appliance” paragraph, above.
5. Remove the overflow cap and shut the door.
6. Push the “start” button, shown to drain.
•
With the tank completely empty, clean the appliance as described in the “Maintenance”
paragraph.
•
Turn off the appliance whenever the overflow cap is removed.
4.7
Regenerating the Ion Exchange Resins
If the machine is equipped with an internal softener (available on request), in order to ensure its
correct performance, it is necessary to periodically regenerate the ion exchange resins. The number
of cycles between each regeneration is set by the hardness of the water, according to the following
table.
dH F
No. of
Cycles
dH F
No. of
Cycles
dH F
No. of
Cycles
dH F
No. of
Cycles
6,0
10 153 9,5 17 107 13,5
24 73 17,5
31 52
6,5 11 147 10,0 18 100 14,0 25 70
18,0 32 50
7,0 12 140 10,5 19 93 14,5 26 67
18,5 33 48
7,5 13 133 11,0 20 87 15,0 27 63
19,0 34 47
8,0 14 127 12,0 21 83 15,5 28 60
19,5 35 43
8,5 15 120 12,5 22 80 16,0 29 57
9,0 16 113 13,0 23 77 17,0 30 53
•
It is suggested to carry out the regeneration during breaks.
•
Turn off the appliance as indicated in paragraph “Turning off the appliance”.
•
Drain the appliance as indicated in paragraph “Discharging the appliance”.
•
Clean the dishwasher as directed in chapter “Maintenance”. At the end of the cleaning
procedure, open the main water tap and engage the main electrical switch.