NOTICE 

Incorrect measured values can 
result from unsuitable installation 
location!

 

 Do not install the THR 10 where it 

would be subject to direct exposure 
to sun rays. 

 Do not use the THR 10 in an area 

prone to draughts, hot or cold air, 
e.g. near a cooker, fridge, radiator, 
etc. 

 Do not install the THR 10 in a unit 

with other heat-generating devices, 
e.g. a dimmer switch. 

 

8.

 Installation / Electrical connection 

 

DANGER 

Danger to life from electric shock 

 Switch the mains fuse off. 

 Position a warning notice to avoid the 

unit being accidentally switched back 
on. 

 

DANGER 

Danger of short-circuits caused by 
pulling the power cable out. 

 Install an external tension relief. 

NOTICE 

Danger of short-circuits caused by 
damp if the power cable is not 
inserted in the housing correctly. 

 Insert the power cable correctly. 

 Take off cover [1]. To do this, press the clip on the 

lefthand side of the housing gently inwards using a 
screwdriver and pull the cover off. 

 Fix the housing lower part [4] to the wall with two 

screws (see arrow in the picture in Chapter 3.2). 
Suitable mounting material is to be supplied by 
the customer. 

 Remove the terminal cover [8] and connect the 

cables to the connection terminal [6] as shown in 
the wiring diagram. 

 

If the temperature range should be limited, 

separate the two pins [7] from the housing 
lower part. 

 Fit terminal cover [8]. 

 Locate the housing [1] onto the housing lower 

part [4] such that it locks into place. 

 Switch the mains fuse on. 

8.1 Start-up 

 Check that the technical data has been adhered 

to, by reference to the rating plate. 

 Carry out a function test. 

 

9.

 Limiting the temperature range 

 

DANGER 

You need to use the two pins [7] to 
limit the temperature range, see 
"Electrical connection" Danger to 
life from electric shock when the 
unit is open.

 

 Switch the mains fuse off. 

 Position a warning notice to avoid the 

unit being accidentally switched back 
on. 

 Remove the rotary knob [5] with a screwdriver. 

 

 
 
 
 

 Plug both pins [7] onto the back of the rotary 

knob, see picture. Temperature range: Minimum 
setpoint 10° C, maximum setpoint 30° C. 

 Reattach the rotary knob [5]. Take note of the 

location of the flattened side, to ensure correct 
positioning. 

 

10.

 Maintenance 

The unit is maintenance-free. 

 

11.

 Dismantling 

 

DANGER 

Danger to life. Unit is powered 
up. 

 S

witch the mains fuse off. 

Dismantling should only be carried out by a trained 
electrician. 

 

12.

 Disposal 

Not in domestic waste. 

The unit contains in part material that can be 
recycled and in part substances that should not 
end up as domestic waste. 

 Dispose of the unit once it has reached the end 

of its working life according to the regulations 
valid where you are. 

 

13.

 Wiring diagram 

 

To apply operating 

  

display [2] bridge  

  

terminals 4 and 5. 

14.

  

 
 
 
 
 
 
 
 
 

 

Maico Elektroapparate-Fabrik GmbH 

  

Steinbeisstr. 20 

  

78056 Villingen-Schwenningen 

  

Germany 

  

S49 7720 694 447 

  

[email protected] 

R

LF.

2_

07.

10

_D

S

W_S

M

 

07.

10

 

Summary of Contents for THR 10

Page 1: ...eige 3 Schalter Sommer Winter 4 Gehäuseunterteil 5 Drehknopf 6 Anschlussklemme 7 Stecker Temperaturbereich 8 Klemmenabdeckung 4 Technische Daten Siehe auch Typenschild Bemessungsspannung 230 V Netzfrequenz 50 Hz 60 Hz Schutzart IP 30 Maximalbelastung induktiv 2 A Maximalbelastung ohmsch 10 A Schaltdifferenz ca 1 K Sensibilität 1 K 15 min Abmessung BxHxT 76 x 82 x 38 mm 5 Umgebungsbedingungen und G...

Page 2: ...ung in das Gehäuse Netzleitung korrekt einführen Gehäuse 1 abnehmen Dabei auf der linken Ge häuseseite mit Schraubendreher die Rastung leicht nach innen drücken und Abdeckung abziehen Gehäuseunterteil 4 mit 2 Schrauben an der Wand befestigen siehe Pfeile in Abbildung Kapitel 3 2 Geeignetes Befestigungsmaterial ist bauseitig bereitzustellen Klemmenabdeckung 8 entfernen und Leitungen an Anschlusskle...

Page 3: ...device must not be used as a toy Installation electrical connections and repairs only permitted when carried out by trained specialists Only connect device to permanently wired electrical installations with NYM O or NYM J 3 x 1 5 mm type cables Fixture for dis connectting from mains with at least 3 mm contact opening needed per pole The fan unit may only be operated using the voltage and frequency...

Page 4: ...terminal cover 8 Locate the housing 1 onto the housing lower part 4 such that it locks into place Switch the mains fuse on 8 1 Start up Check that the technical data has been adhered to by reference to the rating plate Carry out a function test 9 Limiting the temperature range DANGER You need to use the two pins 7 to limit the temperature range see Electrical connection Danger to life from electri...

Reviews: