NOTICE
Incorrect measured values can
result from unsuitable installation
location!
Do not install the THR 10 where it
would be subject to direct exposure
to sun rays.
Do not use the THR 10 in an area
prone to draughts, hot or cold air,
e.g. near a cooker, fridge, radiator,
etc.
Do not install the THR 10 in a unit
with other heat-generating devices,
e.g. a dimmer switch.
8.
Installation / Electrical connection
DANGER
Danger to life from electric shock
Switch the mains fuse off.
Position a warning notice to avoid the
unit being accidentally switched back
on.
DANGER
Danger of short-circuits caused by
pulling the power cable out.
Install an external tension relief.
NOTICE
Danger of short-circuits caused by
damp if the power cable is not
inserted in the housing correctly.
Insert the power cable correctly.
Take off cover [1]. To do this, press the clip on the
lefthand side of the housing gently inwards using a
screwdriver and pull the cover off.
Fix the housing lower part [4] to the wall with two
screws (see arrow in the picture in Chapter 3.2).
Suitable mounting material is to be supplied by
the customer.
Remove the terminal cover [8] and connect the
cables to the connection terminal [6] as shown in
the wiring diagram.
If the temperature range should be limited,
separate the two pins [7] from the housing
lower part.
Fit terminal cover [8].
Locate the housing [1] onto the housing lower
part [4] such that it locks into place.
Switch the mains fuse on.
8.1 Start-up
Check that the technical data has been adhered
to, by reference to the rating plate.
Carry out a function test.
9.
Limiting the temperature range
DANGER
You need to use the two pins [7] to
limit the temperature range, see
"Electrical connection" Danger to
life from electric shock when the
unit is open.
Switch the mains fuse off.
Position a warning notice to avoid the
unit being accidentally switched back
on.
Remove the rotary knob [5] with a screwdriver.
Plug both pins [7] onto the back of the rotary
knob, see picture. Temperature range: Minimum
setpoint 10° C, maximum setpoint 30° C.
Reattach the rotary knob [5]. Take note of the
location of the flattened side, to ensure correct
positioning.
10.
Maintenance
The unit is maintenance-free.
11.
Dismantling
DANGER
Danger to life. Unit is powered
up.
S
witch the mains fuse off.
Dismantling should only be carried out by a trained
electrician.
12.
Disposal
Not in domestic waste.
The unit contains in part material that can be
recycled and in part substances that should not
end up as domestic waste.
Dispose of the unit once it has reached the end
of its working life according to the regulations
valid where you are.
13.
Wiring diagram
To apply operating
display [2] bridge
terminals 4 and 5.
14.
Maico Elektroapparate-Fabrik GmbH
Steinbeisstr. 20
78056 Villingen-Schwenningen
Germany
S49 7720 694 447
R
LF.
2_
07.
10
_D
S
W_S
M
07.
10