8 Installation
36
• Imbalance may arise if the maximum stated
cable lengths are exceeded. Observe installa-
tion requirements relating to cable lengths and
types.
• The ventilation units may only be operated us-
ing the voltage and frequency shown on the rat-
ing plate. For rating plate, see
RLS 45 O
or
RLS 45 K
control or
PPB 30 RC
ventilation unit.
Operating voltage for
PPB 30 O
/
PPB 30 K
units = 12 V DC.
• Units/controls not suited for outdoor use. Pro-
tect ventilation units/controls from moisture and
wetness.
• Use
RLS
/
DS
controls only outside protection
zones 0, 1 and 2.
• Use
PP 45
ventilation units only outside pro-
tection zones 0, 1 and 2.
• Use
PPB 30 O
PPB 30 K
ventilation units only
outside of protection zone 0.
• Use
PPB 30 RC
ventilation units only outside
of protection zones 0 and 1.
•
PPB 30 O units
are connected directly to the
fan interface (Fan1/Fan2) of the RLS 45 O or
RLS 45 K control. For electrical connection →
•
PPB 30 K units
are connected to the
RS 485
bus of the RLS 45 K control
. If using several
PPB 30 K
on an
RLS 45 K
, the
PPB 30 K
units
should be addressed using the DIP switches on
the board (address 0 = unit 1, address 1 = unit
2, address 3 = unit 3). For electrical connection
and position of the DIP switches →
.
•
PPB 30 RC
units are connected to 230V/50Hz
(for electrical connection →
out with
DS 45 RC
radio control.
• The two connecting cables of the
PPB 30
fans
(in the slide-in module) are already fully wired
(8-pin, coded connector plug to avoid mixing up
the sockets). They are connected to the circuit
board in the ventilation unit.
•
RLS
room air control with plug-in connection
terminals for ventilation unit connecting cables.
Connection terminals can be taken off for wir-
ing.
• When using the sensor-based automatic dehu-
midification function, exhaust air mode runs un-
til the humidity falls 3% below the maximum hu-
midity value limit. Volumetric flow compensation
with other PushPull units is undertaken.
• Manually switched exhaust air mode or manu-
ally switched intensive ventilation is possible on
PPB 30 K
units with a button or switch
(provided by the customer). When using the
switch, the start delay can be set. The specialist
installer can set parameters for the duration of
the manually switched functions and the start
delay using the commissioning software. Volu-
metric flow compensation is undertaken with
the other PushPull units on the fan interface.
• Manually switched exhaust air mode or intens-
ive ventilation is possible on
PPB 30 RC
by
means of
DS 45 RC
or a button (provided by
the customer). The duration of the manually
switched function can be parameterised by the
specialist installer via the service mode.
• Exhaust air mode on
a
PPB30 O in combination
with an RLS 45 O can be activated by pressing
the “Ventilation level” button for more than 2
seconds. Exhaust air mode generally lasts 10
minutes.
• Exhaust air mode is only possible with a
PPB
30
unit type and when 1 unit is used (setting in
service menu). The measurements will be in-
correct if the installation location of the control
and external sensors is inappropriate. Avoid
disturbing influences and direct sunlight.
•
RLS 45 O
/
RLS 45 K
with LEDs. For
RLS 45
K
, the brightness can be set and/or switched off
using the commissioning software. If people are
being disturbed by bright LEDs (in bedrooms,
for example), choose a suitable installation loc-
ation.
• Quiet changeover noises when the fans change
direction of rotation. Do not install
PPB 30
in
bedrooms.
8.2 Unit structure and positioning
1 Wall sleeve
2 Slide-in module
Summary of Contents for PPB 30 O
Page 3: ...Steuerungskonzept PPB 30 3 Steuerungskonzept PPB 30...
Page 4: ...Steuerungskonzept PP 45 RC PPB 30 RC Funk 4 Steuerungskonzept PP 45 RC PPB 30 RC Funk...
Page 29: ...PPB 30 control concept 29 PPB 30 control concept...
Page 30: ...PP 45 RC PPB 30 RC wireless control concept 30 PP 45 RC PPB 30 RC wireless control concept...
Page 53: ...Concept de commande PPB 30 53 Concept de commande PPB 30...
Page 54: ...Concept de commande PP 45 RC PPB 30 RC radio 54 Concept de commande PP 45 RC PPB 30 RC radio...
Page 95: ...Produktdatenbl tter Product data sheets Fiches techniques du produit 95 PPB 30 O...