INSTALLATION INSTRUCTIONS

ECA 100 ipro KVZC

Version: 2016-06-24 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 6

The minimum distance from the wall must be observed (see wall mounting as well).

Install the wall sleeve or duct.

Surface- or recessed-mounted connecting cable guide.

ECA 100 ipro and ECA piano only available as recessed-mounted fans.

Drain off any condensation present in the duct using a siphon. Fit a T-piece with siphon in the duct (odour seal) for this

purpose.

Proper duct insulation reduces the build-up of condensation considerably.

Use a roof cowl with the condensation drain pointing outwards, see recommended accessories.

1

ECA fan

2

Sleeve WH ...

3

Duct, DN 100, DN 125 or DN 150

4

Masonry

5

Plaster

6

Insulation

7

DF/DP roof cowl (DN 125/160, possibly adapted by customer)

8

Condensation drain (siphon), provided by customer