INSTALLATION INSTRUCTIONS
ECA 100 ipro KVZC
Version: 2016-06-24 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice
Page 5
EV - Start delay
SB - Switch operation
NZ - Overrun time
Wall mounting of ECA small room fans
Please note the following points when fitting ECA 100 ipro, ECA 150 ipro, ECA piano and ECA 120 series model fans in a
wall:
■
A minimum distance between the wall and the ceiling must be observed when preparing the wall breakthrough, see dia-
gram.
■
Fit a wall sleeve.
■
Feed in the connecting cable for surface or recessed mounting.
■
ECA 100 ipro and ECA piano only available as recessed-mounted fans.
■
Secure the fan using screws during installation.
■
The AP shutter prevents cold air from entering when the fan is switched off. Not required with ECA piano and all versions
with electrically-operated internal shutter.
1
ECA fan
2
WH wall sleeve
3
AP outside shutter
4
Masonry
5
Plaster
6
Cable entry
Ceiling installation with roof cowl
Please note the following points when fitting ECA 100 ipro, ECA 150 ipro, ECA piano and ECA 120 series model fans in a
ceiling in ventilation systems with a roof cowl: