27
PEAK
|
US
Fault
Cause
Remedy
• The
overcurrent
circuit-breaker has
been tripped.
Check if the release bu on
on the circuit-breaker has
popped out. If necessary,
push it in again. If the bu on
con nues to pop out, consult
your dealer at the address
given in the
“
Service
”
sec on.
• The electric fuse
has been tripped.
Check the electric fuse. Reset
or replace it. Check whether
other electric consumers are
connected to this fuse and, if
necessary, unplug them.
If the fuse is tripped
repeatedly, consult your
dealer at the address given in
the
“
Service
”
sec on.
The grinder’s
dosing accuracy is
decreasing.
• The spout is
blocked. Too much
ground co
ff
ee has
become blocked
inside the grinder.
With the grinder switched
o
ff
, clean the spout from
the outside with the brush.
Set the grind to “10” and
start the grinding process.
The grinder clears itself.
Then put the grind se ng
back to the grind you require
while the grinder is running.
• The
built-in
grinder spout is
damaged.
Consult your dealer at the
address given in the
“
Service
”
sec on.