en
|
6
|
Responsibilities/Specifications
ROU250
4.
Responsibilities
4.1
Receiving inspection
Before attempting to operate this equipment,
thoroughly read and understand this manual.
Completely remove all tape and packaging. Inspect the
equipment immediately upon delivery. If shipping
damage is evident, inform the delivery carrier
immediately, and contact MAHLE Service Solutions
using the contact information on the back cover of this
manual.
4.2
Owner
and/or
operator
responsibilities
The owner of this equipment must read these
instructions and maintain them for future reference and
for instructing any other users of the equipment. The
owner is responsible for keeping all warning labels and
instruction manuals legible and intact. Replacement
labels and literature are available from the MSS. The
owner must never authorize or allow anyone to use this
equipment until the operator has read and understood
the information in this manual and on the
accompanying labeling of the equipment itself.
If this equipment is being used in an occupational
setting (or workplace), the employer should ensure that
all personnel working with and around the equipment
know of the risks associated with its use. Personnel
involved in the use and operation of this equipment
shall be careful, competent, trained, and qualified in the
safe operation of the equipment and its proper use
when servicing motor vehicles and their components.
Safety information provided with this equipment should
be emphasized by the employer and understood by
each employee. The employer must make this manual
available to all personnel using this equipment and all
personnel must read and understand the contents of this
manual. If the operator is not fluent in English, the
manufacturer’s instructions and warnings shall be read
to and discussed with the operator in the operator’s
native language by the employer, making sure that the
operator comprehends its contents and observes the
proper procedures for use of this equipment.
5.
Specifications
5.1
ROU250
Model ROU250
Refrigerants
Cat.III: R-12, R-134a, R-1234yf,
R-401c, R-406A, R-500
Cat.IV: R-22, R-401A, R-401B,
R-402B, R-407C, R-407D,
R-408A, R-409A, R-411A, R411B,
R-412A, R-502, R-509
Cat.V: R402A, R-404A, R-407A, R-407B,
R-410A, R-507
Voltage
110-127 VAC 60Hz
Compressor
1/2HP Oil-less
Max Current
8 Amps @ 60Hz
HP Shutdown
38bar/550psi
LP Shutdown
338mbar (10 In/Hg)
80% Capacity Shut-off
When OFP cable is
connected to tank OFP switch
Recovery
Rate
Cat. III
Cat. IV
Cat. V
Vapor
0.23 kg/min
0.51 lb/min
0.25 kg/min
0.55 lb/min
0.26 kg/min
0.57 lb/min
Liquid
1.57 kg/min
3.46 lb/min
1.81 kg/min
3.99 lb/min
1.85 kg/min
4.10 lb/min
Push
Pull
4.64 kg/min
10.23 lb/min
5.57 kg/min
12.28 lb/min
6.22 kg/min
13.71 lb/min
Operating Temp
0-40
˚C / 32-104˚F
Case
Blow Molded High Impact Polyethylene
Dimensions
19.1"Lx8.7"Wx14.4"H
48.5cm L x 22.1cm W x 36.6cm H
Net Weight
33lbs (15kg)
Summary of Contents for ROU250
Page 1: ...MAHLE ROU250 EN Operation Manual Recovery Only Unit...
Page 13: ...ROU250 en 13 System Kits 8 5 ROU250 Complete Kit R1234yf R134a With Tank P N 460 80425 00...
Page 15: ...ROU250 en 15 Schematics 9 Schematics 9 1 Electrical Schematic...
Page 16: ...Notes ROU250 ROU250 en 16 Schematics 9 2 Flow Schematic...
Page 18: ...Notes ROU250 en 18 Notes ROU250 en 18 Notes...
Page 19: ...ROU250 en 19 Parts Diagram...