Tank top return-line filter Pi 5000 NG 40-100
6
8. Technical specifications
Design:
tank top mounting filter
Nominal pressure:
10 bar (140 psi)
Test pressure:
13 bar (180 psi)
Temperature range:
-10 °C to +80 °C
(other temperature ranges on request)
Bypass setting:
3.5 bar ± 10%
Filter head material:
GD Al
Filter housing material:
plastic
Sealing material:
plastic
Maintenance indicator setting
PiS 3084/85:
2.2 bar ± 10 %
Electrical data of maintenance indicator:
Max. voltage:
250 V AC/200 V DC
Max. current:
1 A
Contact load:
70 W
Type of protection:
IP 65 in inserted and
secured status
Contact:
normally open/closed
Cable sleave:
M20x1.5
-
.
The switching function can be changed by turning the electric upper
part by 180° (normally closed contact or normally open contact). The
state on delivery is a normally closed contact. By inductivity in the
direct current circuit the use of suitable protection circuit should be
considered. Further maintenance indicator details and designs are
available in the maintenance indicator data sheet.
_
We draw attention to the fact that all values indicated are avera-
ge values which do not always occur in specific cases of applicati-
on. Our products are continually being further developed. Values,
dimensions and weights can change as a result of this. Our specia-
lized department will be pleased to offer you advice.
_
With the inrush current of 70 VA the indicator can trigger small con-
tactors or contactor relays.
Inductivity in the direct current may require the use of a signal sup-
pressor.
_
Recommended max. flow rate of the filling unit at viscosity of 500
mm²/ s and a degree of filtration 3 µm: NG 40 = 8 l /min, NG 63 =
15 l /min, NG 100 = 25 l /min.
9. Dimensions
All dimensions except "D" in mm.
Type
A
B
C
D*
E
DIN 2999
F
Weight
[kg]
Pi 50004
208
159
131
G1
G1
100
0.65
Pi 50006
268
219
191
G1
G1
130
0.68
Pi 50010
358
309
281
G1
G1
200
0.74
*NPT- and SAE- connections on request
1
= Standard maintenance indicator visual PiS 3084
1 + 2 = Standard maintenance indicator electrical PiS 3085
3
= Pressure switch
4
= Pressure gauge 0 to 6 bar
5
= Quick release coupling for filing