EN | 17 | AIR-NEX 9350/9450 Commissioning
© MAHLE
8
Commissioning
8.1
Connections
The unit has to be positioned on a
horizontal surface to ensure the correct
operation.
The unit has to be connected to the
electric mains following instructions on
the identification plate of the unit applied
next to the main switch, mainly as to
applicable voltage and power.
The A/C service stations are
designed for 230VAC, 50Hz.
Follow the information on the
rating plate.
8.1.1
Positioning and connection
HANDLING: During handling, the
minimum devices required for
correct handling shall be ensured,
as provided for by accident
prevention provisions.
POSITIONING: Place the unit in a
stable place. The location must
be well ventilated, with a good
rate of change of air. The unit
must be located at least 10 cm
from any potential obstacles to its
internal ventilation. Keep the unit
away from rain and excessive
humidity as they can irreparably
damage it. In addition, the
equipment must never be directly
exposed to the sunrays or to
excessive dust.
INSTALLATION: the unit must be
installed by a specialized
technician
in scrupulous
observance of in accordance with
electrical engineering principles.
The use of the equipment in
explosive atmosphere is
forbidden.
CONNECTIONS: since the unit is
connected to the main power
supply, it must be properly
grounded with its power plug
GND pin. Failure to ground the
unit can damage it and
constitutes a risk of fatal injury to
the operator. Position the unit so
that the power plug is easy for the
operator to access.
Fig. 4: Rear view (detail)
1
Power cord connector and Power
switch
2
HP&LP vehicle connector/couplers
and hoses
ATTENTION: Leave the quick
coupling taps closed when the
unit is not in use and at the end of
vehicle service operations.
2
1