Before approach the unit wear the personal protective systems

The responsibility for the effects on people, animals or property resulting from inspection and repair work is entirely attri

the technician who works on the equipment. The suggestions given on the following pages are only indicative and the 

manufacturer declines all responsibility for them.

Alarm messages are coded Axxx in the window title bar.

CODE 

MESSAGE 

When it occurs

A000 

EEPROM NOT WORKING 

In case of faults in the 
EEPROM memory

A001 

EEPROM DATA CORRUPT 

In case of faults in the 
EEPROM 

A002 

PRESSURE SAFETY SWITCH 
ACTIVATED 

High pressure is over 18 
bar

A003 

ADC NOT WORKING 

After turning on the 
equipment

A004 

FAN NOT WORKING 

Only during R
use

A006 

EAXXXX not working 

Electronic board 
problems

A009 

SENSORS ERROR: 

Sensors not connected 
or in short circuit

A032 

CIRCUIT STILL UNDER 
PRESSURE 

During vacuum, 
filling or leak test phase 
in vacuum

A033 

CIRCUIT LEAKAGE 

During vacuum, 
recharge or leak test 
phase

A034 

VACUUM LEVEL TOO LOW 

During 

A035 

BOTTLE EMPTY 

During the gas charging
and flushing phase

A036 

BOTTLE REFRIGERANT 
QUANTITY TOO LOW 

During the gas charging
and flushing phase

A037 

FURTHER REFRIGERANT 
CHARGE NOT POSSIBLE 

During gas 
phase

A038 

CIRCUIT LEAKAGE OR 
DISCONNECTED 

During flushing phase

 

| ACX380/480

Before approach the unit wear the personal protective systems 

The responsibility for the effects on people, animals or property resulting from inspection and repair work is entirely attri

the equipment. The suggestions given on the following pages are only indicative and the 

manufacturer declines all responsibility for them. 

 

Alarm messages are coded Axxx in the window title bar. Alarms immediately terminate the procedure and prevent its

When it occurs 

Possible situations 

Possible solutions

In case of faults in the 
EEPROM memory 

EEPROM damaged 

Change the logic electronic 
board 

In case of faults in the 
EEPROM memory 

EEPROM damaged 

Change the logic electronic 
board 

High pressure is over 18 
bar 

High pressure (due to 
pressure on bottle or  
circuit to bottle closed) 
on refrigerant circuit 
between equipment’s 
compressor and internal 
bottle. 

Verify  
If internal 
is over 18 bar, wait for 
pressure reduction
disconnect equipment from the 
mains, use safety protection, 
open equipment and make 
sure the valves between 
compressor and internal 
are open 

After turning on the 
equipment 

ADC fault 

Replacement of logic 
electronic board.

Only during R-1234yf 
use 

Fan not working properly 
(stopped or fan’s rpm 
not adequate) 

Stop use of the equipment 
check fan connections and 
if necessary, change fan and 
related cables with a new one 
change logic electronic board 
with new one.

Electronic board 
problems 

Faults on the electronics 
components or 
connections 

Updates the firmware

Sensors not connected 
or in short circuit 

Sensors disconnected or 
damaged. 

To check electrical 
connections or change with 
new spare part.

During vacuum, bottle 
filling or leak test phase 
in vacuum 

The vehicle A/C system 
is pressurized 

Recover the refrigerant gas 
from the vehicle before starting 
another vacuum phase.

During vacuum, bottle 
recharge or leak test 
phase 

Leakage in the circuit or 
in the vehicle fittings. 

Identify the leak position in the 
vehicle or connected system 
and have it repaired by trained 
and qualified staff according to 
local legislation. 

During charging phase 

Vehicle A/C system is 
pressurized 
notwithstanding the 
vacuum phase 

Identify the leak position in the 
vehicle or connected system 
and have it repaired by trained 
and qualified staff according to 
local legislation. 

During the gas charging 
and flushing phase 

Refrigerant gas is too 
low for the procedure to 
be completed 

Fill the internal tank

During the gas charging 
and flushing phase 

Gas amount in internal 
tank less than required 

Fill the internal tank

During gas charging 
phase 

Hoses not hooked up to 
A/C system; tap closed; 
vacuum not sufficient; 
presence of pressure in 
the circuit 

Caution: before proceeding, 
empty out the hoses.
Repeat the recovery procedure 
and increase the
phase duration.

During flushing phase 

Leakages or 
obstructions in the 
circuit to be flushed 

Check the connection to the 
A/C system or identify the leak 
in the circuit and have it 
repaired by trained and 
qualified staff according to 
local legislation.

ACX380/480 | 42       en

 

The responsibility for the effects on people, animals or property resulting from inspection and repair work is entirely attributable to 

the equipment. The suggestions given on the following pages are only indicative and the 

Alarms immediately terminate the procedure and prevent its resumption. 

Possible solutions 
Change the logic electronic 

Change the logic electronic 

If internal bottle pressure level 
is over 18 bar, wait for 
pressure reduction 
disconnect equipment from the 
mains, use safety protection, 
open equipment and make 

re the valves between 

compressor and internal bottle 

 

Replacement of logic 
electronic board. 
Stop use of the equipment  
check fan connections and  
if necessary, change fan and 
related cables with a new one  
change logic electronic board 
with new one. 
Updates the firmware 

To check electrical 
connections or change with 
new spare part. 
Recover the refrigerant gas 
from the vehicle before starting 
another vacuum phase. 
Identify the leak position in the 
vehicle or connected system 
and have it repaired by trained 
and qualified staff according to 
local legislation.  
Identify the leak position in the 
vehicle or connected system 
and have it repaired by trained 
and qualified staff according to 
local legislation.  
Fill the internal tank 

Fill the internal tank 

Caution: before proceeding, 
empty out the hoses. 
Repeat the recovery procedure 
and increase the vacuum 
phase duration. 
Check the connection to the 
A/C system or identify the leak 
in the circuit and have it 
repaired by trained and 

ed staff according to 

local legislation. 

Summary of Contents for ACX380

Page 1: ...MAHLE ACX380 480 EN Service Manual A C Service Equipment...

Page 2: ...rigerant fluid circuit 17 11 1 Refrigerant fluid circuit 17 11 2 Operational cycles 18 11 3 Receiving tank refrigerant cylinder 18 11 4 Manifold charts 18 11 5 NITROGEN TEST and FORMING GAS LEAK TEST...

Page 3: ...ing of the planet The release of refrigerant gas R134a into the atmosphere is forbidden by laws that were enacted within the framework of the Kyoto protocol For information only we will mention in par...

Page 4: ...h an original spare part or equivalent by a MAHLE centre Before opening the service station extract completely the supply cable from the plug or you can get an electric shock Do not tamper with or byp...

Page 5: ...f instructed or certified for the equipment open the equipment The equipment parts which can cause electrocution shut off power to the equipment before servicing repairing it 2 3 Safety devices The A...

Page 6: ...by the vehicle s manufacturer Charge filling of refrigerant into the A C system in the amount specified by the manufacturer System flushing Cleaning phase for the removal of possible polluting substa...

Page 7: ...ant recovery and recharging Vacuum generation Flushing 4 2 Scope of delivery Description Service hose high pressure Service hose low pressure Quick release coupling high pressure Quick release couplin...

Page 8: ...are available on the display Icon Description Device connected via WiFi The residual refrigerant weight in kg and with visual bar to enable disable the bar by vertically swiping your finger from top t...

Page 9: ...menu The Main menu of the graphical user interface allows to select the following functions Vehicle selection OneClick Cycles Additional Functions Maintenance Setup Secured Service not available for u...

Page 10: ...014 68 EU IV Pneumatic fittings Net length of external HP and LP hoses 4 5 m HP and LP Analog 80 mm pressure gauges pulse free 1 0 class Display Touch screen 7 TFT colours Keypad Touch screen Software...

Page 11: ...for correct handling shall be ensured as provided for by accident prevention provisions POSITIONING Place the unit in a stable place The location must be well ventilated with a good rate of change of...

Page 12: ...coupler Tanks without plunger have only one valve so they must be turned upside down to transfer the liquid refrigerant The LP gauge indicates the pressure inside the external tank After some minutes...

Page 13: ...side the auto vehicle A C system To fill the UV dye bottle Fig 1 Pos 9 it has to be extracted from its housing by means of the quick coupler on the top of the bottle slightly press downward the couple...

Page 14: ...the garage data to be printed at the bottom of the cycle report LANGUAGE by selecting this entry any language present in the database may be set In case you choose a language with unintelligible char...

Page 15: ...ot connected to the bottle station accessories kit when the next message is displayed Fig 16 LP quick coupler opening Turn the LP quick coupler clockwise to open it and press enter OK so that air gets...

Page 16: ...pening Turn the LP quick coupler clockwise to open it and press enter OK so that air gets into the LP hose Wait for the message to connect the reference gauge contained in the service kit and by rotat...

Page 17: ...far from the value of the certified reference weight the result is negative in this case is not possible to update calibration It is necessary to carry out the 3 points Gas weight calibration mention...

Page 18: ...ation is not jeopardized VESSEL 20l Category III Dir 2014 68 EU Fig 20 Refrigerant internal bottle SAFETY VALVE GAS AIRTEK VS14NPT20HNBRPED4 PS 20 bar R 1 4 NPT Category IV Dir 2014 68 EU 11 4 Manifol...

Page 19: ...n MAHLE Fig 22 Manifold circuit Fig 23 Manifold valves Fig 24 Manifold with pressure sensors installed V A I R L1 V A I L2 R T1 T1 L1 R A V PS TP PS HP PS LP One way valve L2 V A I L2 R T1 L1 R A V PS...

Page 20: ...LD The unit has a second manifold dedicated to nitrogen test the identification letters of the sectioning valves are highlighted is reported as follows T2 nitrogen input N IN X nitrogen output N OUT X...

Page 21: ...izes when air is absent and when in contact with metal its aim is preventing slackening caused by impacts and vibrations Yet after application and fixing onto the junction thread you must tighten and...

Page 22: ...and scroll to MAINTENANCE and then select Fig 26 Maintenance screens Only for model ACX380 REFRIGERANT TYPE CHANGE With this function allows the service assistance technician to change the Refrigeran...

Page 23: ...he main menu select MAINTENANCE and press PRESSURES ZERO This function allows to determine and store the at pressure value We recommend running this procedure every time the A C service station will b...

Page 24: ...er to zero and to start the filter replacement procedure Insert the code of the new filter Now you can replace the filter Required tools 1 flat screwdriver 1 cross screwdriver 1 regular or torque Hex...

Page 25: ...and press CALIBRATION CHECK This function allows to check the status of gas weight scale measure with a reference weight from 100 g to 10000 g maximum not included in the scope of delivery When reque...

Page 26: ...ovide for a the bodies in charge after the results of the previous checks performed of commissioning or period requalification do not establish different The checks must be performed by the bodies in...

Page 27: ...install the specific components for use of R1234yf He will also carry nfigurations and verifications required by the the MAINTENANCE 14 17 Replacing white sample filter Refrigerant identification unit...

Page 28: ...ronic power board Replacement of power supply board 15 2 Extraordinary maintenance 15 2 1 Replacement of component connected to refrigerant circuit The components pressurised equipment constituting co...

Page 29: ...tery Evident damage to board components and circuits For the replacement of the board it is recommended to position the new board alongside the one to be replaced Disconnect and reconnect the cables i...

Page 30: ...C SERVICE STATION ACX380 480 Blue LP quick coupler and red HP quick coupler Active Oil Protection kit 2 pcs New Oil 1 UV dye rts are available through the Service Centers USING NON ORIGINAL UNAPPROVE...

Page 31: ...en 31 ACX380 480 APPENDIX 1 REFRIGERANT FLUID CIRCUIT ACX380 480 H...

Page 32: ...ACX380 480 32 en APPENDIX 2 REFRIGERANT FLUID CIRCUIT ACX380 480 OPERATIONAL CYCLES Uncondensable gases H...

Page 33: ...en 33 ACX380 480 Recovery cycle H...

Page 34: ...ACX380 480 34 en Vacuum H...

Page 35: ...en 35 ACX380 480 Recharge H...

Page 36: ...load cell dye 1 10 LC New Oil1 input load cell new oil 1 11 PS Tank input pressure sensor tank 12 LC Ex Oil input load cell 13 PS LP input pressure sensor LP 14 PS HP input pressure sensor HP 15 TS Ta...

Page 37: ...7 ACX380 480 APPENDIX 4 ACX380 480 ELECTRICAL CONNECTION POWER ELECTRONIC BOARD AND POWER SUPPLY POWER ELECTRONIC BOARD POWER SUPPLY BOARD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 24 2...

Page 38: ...ng 9 OUT H Heat exchanger fan 10 OUT I HP LP solenoid interconnection valve 11 OUT N Solenoid valve for draining of tank s uncondensable gases 12 OUT V Vacuum pump 13 OUT V Vacuum solenoid valve coupl...

Page 39: ...n 39 ACX380 480 APPENDIX 5 ACX380 480 ELECTRICAL CONNECTION STATUS AND WARNING INDICATOR LIGHT ELECTRONIC BOARD Item label Description Connected Unused x 1 SER I O serial I O interface to power board...

Page 40: ...compressor check for leaks from valves R or check compressor functioning Pressure sensor not Altitude compensation and or full pressure calibration Mistake during procedure Altitude compensation and...

Page 41: ...acuum pump oil When the filter capacity is the filter capacity is finished Change filter with new one During the setting of the inner tank charge amount Amount required greater than that available in...

Page 42: ...d or damaged To check electrical connections or change with new spare part During vacuum bottle filling or leak test phase in vacuum The vehicle A C system is pressurized Recover the refrigerant gas f...

Page 43: ...leak test Empty the vehicle follow the procedure guided by the displayed messages A048 HP LEAKAGE During the gas recovery and hoses emptying phase At the end of the gas charging in the E3 Connect qui...

Page 44: ...nalisys not possible Check with virgin refrigerant bottle if the refrigerant gas identifier is working properly If yes and the refrigerant of the car is not R1234yf empty in a safety way and in compli...

Page 45: ...MAHLE Aftermarket Italy S p A Via Quasimodo 4 a 43126 Par ma ITALY 2019 10 28...

Reviews: