| ACX380/480 | 25
en
© MAHLE
14.10
Replacement of Active Oil Protection
Cartridge
After one year or after injecting 2 kg of New Oil or UV dye,
the station will show a reminder suggesting the replacement
of the cartridge. To replace the Active Oil Protection
Cartridge,
from
the
MAINTENANCE
menu
select
CARTRIDGE REPLACEMENT: press “START” to set the
counter to zero and to start the cartridge replacement
procedure of each bottle. Enter the code of the new
cartridge. Now you can replace the cartridge.
14.11
Calibration check
In the main menu select MAINTENANCE and press
“CALIBRATION CHECK”.
This function allows to check the status of gas weight scale
measure with a reference weight (from 100 g to 10000 g
maximum) not included in the scope of delivery. When
requested by the software, put the weight above the scale
plate as in the picture below.
Reference weight
(not included in the scope of delivery)
14.12
Maintenance of printer
To change the roll of paper follow instructions below:
1.
Open the lid of the printer as shown
(note: press the green led as in picture and only after that
open the lid)
2.
Position the roll of paper inside the housing in the rotation
direction indicated in the picture;
3.
Pull the paper out of the housing as indicated in the picture
and close the lid ;
4.
The printer is ready for printing.
Summary of Contents for ACX380
Page 1: ...MAHLE ACX380 480 EN Service Manual A C Service Equipment...
Page 31: ...en 31 ACX380 480 APPENDIX 1 REFRIGERANT FLUID CIRCUIT ACX380 480 H...
Page 33: ...en 33 ACX380 480 Recovery cycle H...
Page 34: ...ACX380 480 34 en Vacuum H...
Page 35: ...en 35 ACX380 480 Recharge H...
Page 45: ...MAHLE Aftermarket Italy S p A Via Quasimodo 4 a 43126 Par ma ITALY 2019 10 28...