Status Indication
Diagnosis
Remedy
Red
Yellow
Green
OFF
OFF
OFF
If no other LEDs are ON:
Radio system switched off
after 30 sec.
Briefly press any button to
enable the radio system.
OFF
OFF
OFF
If other LEDs are ON: Ra-
dio interference (e.g.
Channel, Mode…). Possi-
ble cause:
Devices in the vicinity
transmitting on the
433 MHz band (such as
garage door opener, radio
set…).
Wait until radio interfer-
ence has stopped.
OFF
OFF
OFF
Battery undervoltage
Charge batteries using
power cord.
and control can be ena-
bled only briefly or not at
all.
OFF
OFF
OFF
Fuse blown, hardware
error.
Contact service.
and control cannot be
enabled at all.
OFF
OFF
If no other LEDs are ON:
Emergency-stop actuat-
ed.
Enable emergency-stop
button.
OFF
OFF
Lift is not yet referenced,
when a new column with
new control is being con-
nected after final assem-
bly.
Lower lift with emergency-
down function.
Level difference between
columns too great.
OFF
ON
Lift has contacted ob-
struction or floor or is
blocked by safety wedge.
Raise lift until yellow LED
goes off.
and lift stops while lower-
ing.