4.5
Battery Charge Condition
Pos: 116 /Produktfamilien/Hebetechnik/COLUMNLIFT/491901 RGA/BA/Inhalt: 4919 Ladezustand der Batterien (Bild) @ 16\mod_1246887757945_0.docx @ 402425 @ @ 1
Pos: 117 /Produktfamilien/Hebetechnik/COLUMNLIFT/491901 RGA/BA/Inhalt: 4919 Ladezustand der Batterien (Text)_12pt @ 35\mod_1393427797965_75.docx @ 1911637 @ @ 1
Indication
Charge Condition
Action
RED
Battery flat, only lowering
possible.
Charge at once.
ORANGE/YELLOW
Battery weak, operation may
be continued.
Charge as soon as
possible.
GREEN
Battery fully charged or partly
discharged.
---
Flashing
RED, ORANGE, GREEN
Battery being charged.
---
Switching to GREEN
during charging process
Battery fully charged.
Disconnect mains
plug.
•
The batteries may be charged at any time regardless of the control unit being
on or off. Do not operate unit while charging.
•
To charge the batteries connect the mains plug.
•
The charging process takes approx. 12 h with a flat battery. Overcharging is
not possible.
•
To prevent the batteries from discharging unnecessarily, each control unit
should be disabled completely when the lift is not in use.
•
The batteries should be occasionally charged even when not in use. This is to
ensure that their full capacity is available during lift operation and to compen-
sate for any self-discharge losses.
•
To avoid exhaustive discharge, any column with undervoltage will switch off au-
tomatically.
•
For a long life expectancy the batteries should not be fully discharged.