40
BA022301-en
Pos: 128 /Technis che Dok umentation/A lle G eräte/ Überschr iften/Üb erschriften 1.1/M/ Überschrift 1.1: M SD 3000 @ 24\mod_ 1306488669901_ 0.d ocx @ 1013183 @ 2 @ 1
5.11
MSD 3000
Pos: 129 /Technis che Dok umentation/ Bremsprüftechnik/M BT- SERIES/ 022301 MBT LON/BA/I nhalt: 0223 Bedienung MS D 3000 (Bild er) @ 21\mod_ 1277367161654_ 0.d ocx @ 860633 @ @ 1
Pos: 130 /Technis che Dok umentation/ Bremsprüftechnik/M BT- SERIES/ 022301 MBT LON/BA/I nhalt: 0223 Bedienung MS D 3000 (Text) @ 27\mod_ 1327402629870_75.d ocx @ 1515105 @ @ 1
Test
1 Drive onto the MSD (A). Weight measurement (B)!
2 Both sides start up simultaneously (C).
3 After measurement completion the pointers move to test value 0 to 0.3 D. If the
test value is above 0.3, the pointers move slightly above 0.3 D.
•
The display changes between the unit (D) and the difference (E) in % until the
tester is exited. The differential value is based on the left and right measurement
value.
•
If the measurement value of a wheel is under 0.13 D, or if the difference is
> 29%, then an additional single wheel measurement is done of each wheel.
The display flashes during the single wheel measurement (C).
4 Measurement values are automatically stored without remote control.
With 2 additional AN5-Displays the wheel weight is displayed during the meas-
urement procedure, and the measurement value 0…0.3 is displayed after com-
pleted measurement.
A
B
C
D
E