S
ET
U
P
25
ENGLISH
S
ET
U
P
Before you go for your first ride with your new MAGURA suspension fork,
take some time to adjust the suspension and damping to match your
personal weight and style of riding. This is absolutely necessary to make
best use of your suspension fork’s characteristics.
A
IR
PRESSURE
GUIDELINES
L
Note that the specified air pressure values are for reference only. You
should adjust them for your personal riding style, your seating position,
the characteristics of the road, and the geometry of your bicycle.
Rider weight
Air pressure
kg
lb
bar (± 0.5)
psi (± 7)
50–59
110–124
3.5–3.9
50–52
60–69
125–149
4.0–4.3
53–60
70–79
150–174
4.4–5.0
61–70
80–89
175–199
5.1–5.6
71–78
90–99
200–224
5.7–6.3
79–85
100–109
225–249
6.4–7.0
86–99
110–119
250–274
7.1–8.0
100–114
120–130
275–286
8.1–8.9
115–126
A
DJUSTING
THE
SUSPENSION
(
AIR
PRESSURE
)
L
The air suspension on your MAGURA suspension fork helps to compen-
sate for uneven terrain and keeps your front wheel in contact with the
ground at all times.
Insufficient air pressure causes a pronounced drop, frequent bottoming
out and a spongy ride.
Excessive air pressure reduces the maximum suspension travel and
provokes a hard response from your suspension fork.
As a general rule, the higher your weight and speed, and the rougher
the terrain, the higher the air pressure will need to be.
Material damage due to severe bottoming out caused by insufficient air
pressure.
h
Never use your suspension fork if there is insufficient or no air pressure.
Material damage due to excessive air pressure.
h
Never exceed the maximum permissible air pressure of 10 bar (150 psi).
Air leaking due to incorrect fitting of the valve cover.
h
Never use the suspension fork without a valve cover.
h
Always keep the valve cover seals clean.
h
Always firmly close the valve cover.
)
Remove the valve cover
(
1
)
by turning counter-clockwise
[
F4
]
.
)
Shift the lever
(
2
)
on the pump head to the upper position (Posi-
tion A)
[
F5
]
.
)
Screw the union nut
(
3
)
on the pump head onto the valve until hand
tight.
)
Shift the lever
(
2
)
on the pump head to the lower position (Position B).
Î
The valve pin is pressed in; the valve is open.
Î
You can read off the current pressure on the pump pressure gage.
)
Adjust the air pressure if needed.
L
Pushing the ventilation button
(
4
)
fully gradually reduces the pressure.
Pushing the ventilation button lightly completely evacuates the pressure.
)
Shift the lever
(
2
)
on the pump head to the upper position (Position A).
Î
The valve pin is released; the valve is closed.
Î
No loss of pressure when you remove the union nut.
)
Remove the union nut.
Summary of Contents for TS6
Page 1: ...THE PASSION PEOPLE www magura com OWNER S MANUAL TS8 TS6...
Page 2: ......
Page 5: ...DIAGRAMS ENGLISH 5 A2 A1 H S V L B1 25mm max B3 B2 1 A1 2 1 3...
Page 7: ...DIAGRAMS ENGLISH 7 2N m 18lbf in max 2 5mm E3 10 A B 2 0 0 F5 4 2 3 F1 F4 1...
Page 8: ...DIAGRAMS THE PASSION PEOPLE www magura com 8 H1 sag 20 30 F6 5 G2 MIN MAX 12 14 clics G1...
Page 9: ...DIAGRAMS ENGLISH 9 J2 J3...
Page 10: ...DIAGRAMS THE PASSION PEOPLE www magura com 10...
Page 11: ...DIAGRAMS ENGLISH 11 1s 1s 1s 3h 100 L1 1 2 2 1s 1s 1s 3h 100 L2 1 K1 K2...
Page 12: ...DIAGRAMS THE PASSION PEOPLE www magura com 12 M2 2 3 1 M1 8s min 8s min N1 1 N2...
Page 13: ...DIAGRAMS ENGLISH 13 3s min N3 3 30s 3 30s N4 3 30s N5 2s min N6...
Page 15: ...DIAGRAMS ENGLISH 15 CR 2032 T1 2 1 U1 R3 1 2s 2 0 5s 4 0 25s 1 1 S1...