M A G U I R E P R O D U C T S , I N C .
Rev: January 15, 2019
9
L o P r o R e c e i v e r
Accessing electronics, valves for service
To access the electronics of the Lopro receiver, remove the (7) sheetmetal screws holding in the
front panel. Remove only the front panel.
Replacement Parts:
Part Description
Maguire Part Number
4.5” dia. Dacron filter with foam gasket
ashffd4
Solenoid, 3-way, 24 VDC
nv91
Circuit Board
eab-LPL-R
“Status” Indicator LED, 22mm, 24V Green
ehl-24G
“ON/OFF” Rocker Switch
eswr06
Piezo Alarm Buzzer, 24VDC
ehb-2