M A G U I R E P R O D U C T S , I N C .
Rev: January 15, 2019
7
L o P r o R e c e i v e r
Installing the LoPro Receiver
1. Install flexible hose, secured with hose clamps at both ends, from feed tube to material inlet tube on
the front of loader (same side as controller).
2. Install flexible hose, secured with hose clamps at both ends, from vacuum pump to vacuum inlet of
receiver (opposite side as material inlet).
3. Install 5/32” (4 mm) air line into the fitting and connect to clean, dry 80 psi (5.5 bar) compressed air
supply. DO NOT apply direct air pressure to the LoPro fitting. Damage or an air leak could result.
A compressed air filter (sold separately) is recommended for protection of pneumatic components.
4. Connect the 4-pin power/signal cable to the receptacle labeled “INPUT” on the front panel of the
Lopro. Connect other end of cable to pump (or another LoPro’s “OUT” receptacle that has already
been attached to a pump).
5. Attach pump (shown with Maguire MCP) to electrical power source (120 or 230 volts AC depending
on model), then turn on.
6. Rotate the feed tube ring for the best air to material mixture. The best mixture of air and material
will allow material to flow efficiently, with the right proportion of conveying air, without clogging and
without rapid hose wear.