33
Magtrol TM Series In-Line Torque Transducers
Chapter 2 – Installation / Configuration
2.7.2
c
onnecTIng
c
aBle
The connecting cable to the selected signal processing unit is fitted with a 6-pin Souriau connector
on the transducer side and a 14-pin Centronics connector on the side of the signal processing unit.
The following signals are transmitted (see
Figures 2–18 and 2–19
) :
A
F
E D C
B
A. Power supply 20 to 32 V DC
B. Torque signal -10 to +10 V DC
C. N/C
D. Power supply/torque grounding 0 V DC
E. Test signal (high impedance)
F.
Speed signal (open collector)
Figure 2–18 6-pin Souriau Connector Configuration
Note:
The test function is only active when the input is grounded.
1
4
3
2
8
9
10
11
6
5
12
13
7
14
1.
N/C
2.
N/C
3.
24 V DC
4.
Power supply grounding 0 V DC
5.
Shield
6.
N/C
7.
N/C
8.
N/C
9.
N/C
10. Speed signal
11. N/C
12. Test signal
13. Torque signal grounding 0 V DC
14. Torque signal -10 to +10 V DC
Figure 2–19 14-pin Centronics Connector Configuration