12
Magtrol Model 6200 Open Loop Dynamometer Controller
Chapter 4 – Manually Controlled Operation
OPERA
TION
10. Press ShIFT.
11. Press UP
or DoWN
to turn oN or oFF Speed PASS/FAIL testing.
12. If oN, press ShIFT.
13. Use the UP
or DoWN
buttons and the Decrease/Increase Dial to adjust the high
limit for Speed.
14. Press ShIFT.
15. Use the UP
or DoWN
buttons and the Decrease/Increase Dial to adjust the low
limit for Speed.
16. Press ShIFT.
17. Press UP
or DoWN
to turn oN or oFF Auxiliary Input PASS/FAIL testing.
18. If oN, press ShIFT.
19. Use the UP
or DoWN
buttons and the Decrease/Increase Dial to adjust the high
limit for Auxiliary Input.
20. Press ShIFT.
21. Use the UP
or DoWN
buttons and the Decrease/Increase Dial to adjust the low
limit for Auxiliary Input.
22. Press ShIFT to exit.
4.1.5
s
et
u
P
i/o P
arameters
1. Press and release ShIFT.
2. Press SETUP.
3. Press the DoWN
button twice.
4. Press ShIFT.
5. Press UP
or DoWN
until you see the desired contrast level.
6. Press ShIFT.
7. Press UP
or DoWN
until you see the desired gPIb address.
8. Press ShIFT.
9. Press UP
or DoWN
until you see the desired RS-232 baud rate.
10. Press ShIFT to exit.
4.2
setting dynamometer load
1. Press the UNITS DISPLAY button.
2. Use the Decrease/Increase Dial to adjust the current output to 0%.
3. Use the bRAkE oN/oFF button to turn the brake oN.
4. Start the motor under test.
5. Use the UP
or DoWN
buttons and the Decrease/Increase Dial to adjust the loading
on the motor.
C
aution
:
d
o
not
exCeed
the
Capabilities
oF
the
dynaMoMeter
or
the
power
sourCe
in
use
. M
otors
draw
very
large
Currents
when
held
at
loCked
rotor
,
and
overheating
May
result
.
when
using
open
loop
Current
Control
,
induCtion
Motors
Cannot
be
tested
beyond
breakdown
,
exCept
at
loCked
rotor
.