Section 1. Overview
3
SPECIFICATIONS
Table 1-2 lists the specifications for the ImageSafe Scanner.
Table 1-2. Specifications
OPERATING
Reference Standards
ANSI X9.27
Power Input
12VDC, 1.5 Amp
Current
(Operating Idle)
300 mA
1.5 A Max
MTBF
Electronics: 125,000 hours
Check Read Head: 1,000,000 passes
MSR Read head: 1,000,000 passes
Document Speed
10 ips
Document Size
4"x 9" Maximum
3"x 2.625" Minimum
Image Resolution
200 dpi
MICR fonts supported
E13-B
CMC-7
Interface Options
USB 2.0 or USB 1.1
MECHANICAL
Dimensions
Length 9.0”, Width 3.9”, Height 6.0”
Weight:
2.2 lbs.
Connector:
USB B
ENVIRONMENTAL
Temperature
Operating
0
o
C to 50
o
C (32
o
F to 122
o
F)
Storage
-30
o
C to 70
o
C (-22
o
F to 158
o
F)
Humidity
Operating
10% to 90% non-condensing
Storage
Up to 100% non-condensing
Altitude
Operating
Storage
0 -10,000 ft (0 - 3,048m)
0 - 50,000 ft (0 - 15240m)