AC WIRING DIAGRAM - 3 POSITION VOLTAGE SELECTOR SWITCH
BREAKER
240V 50A
BRN
240V 50A
BREAKER
240V 50A
BREAKER
BLK
BLK
BLK
BLK
BRN
5
9
13
6
10
14
7
8
11
12
15
16
T5
BLK
BLK
PAIR BLK
GRN/YEL
(T7)
CT-3
BRN/WHT
L2
L3
SHUNT
L1
CT-2
CT-1
BLK
GRN/YEL
GRN/YEL
GRN/YEL
PAIR BLK
PAIR BLK
1
2
3
4
T4
BRN/WHT
(2.5K, 2 WATT)
ADJUSTMENT
VOLTAGE
GROUND
TO GEN FRAME
L0
60HZ
50HZ
ON REGULATOR
4 AMP FUSE
WHT
RED F+
F-
F+
3
4
6
7
BRN/WHT
BLK
BLK F-
BRN
MECHANICAL LUGS
GROUND
TO
FRAME
BLK
BLK
50A
240V
RCPT.
BLK
GFCI
RECPT
120V
17
21
25
18
22
26
19
20
23
24
27
28
T9
RCPT.
240V
50A
50A
RCPT.
240V
BLK
BLK
BLK
T6
T8
T10
T11
T7
T1
T12
T2
T3
GENERATOR
F+
F-
120V
20A
BRKER
120V
RECPT
GFCI
L3
L2
L1
L0
SE350
VOLTAGE REGULATOR
12VDC
(T9)
GRN/YEL
BRKER
20A
120V
GND
BLK
RED
LUG DOOR
NO
12
11
SAFETY SWITCH
LT BLU
LT BLU
LT BLU
LT BLU
LT BLU
BLK
BLK
PAIR BLK
(L0)
(3) JUMMPER
WIRES ON PHASE
SWITCH 15-20, 12-17,
10-21
WIRES NOT USED IN
BUCK BOOST OPTION
SEE DC WIRING DIAGRAM FOR CT CONNECTIONS
MAIN
CIRCUIT
BREAKER
21 PIN
PLUG
P
P
N
N
90250_A_03.13.13