If spot welding is set to off, press the lower
knob briefly.
The symbol will flash together with the selected 2t or 4t
option.
The selection is made by turning the lower knob.
Confirmation takes place by another short press of the
lower knob.
If the welder is on 4t, the display during operation
shows the symbol in both manual mode
and synergistic.
If 2t is on, the display does not show
the above symbol.
5.1 Synergic programs and settings.
After confirming the choice of synergic mode, the display shows the current program and other parameters:
- type of material selected,
- wire diameter,
- shielding gas,
- ATC (if material thickness
≤1.5
mm)
- material thickness,
- wire feed speed,
- graphical indicator of the shape of the weld and material thickness,
- welding voltage and current (during welding),
- on 4t.
To enter the menu that allows you to select the type of material, wire diameter and shielding gas, press the lower
knob for at least 2 seconds until the following symbols appear. One of the symbols in the group
materials will flash. By turning the lower knob in
any direction, select the symbol of the required
material (it should flash). Confirm the selection by
briefly pressing the lower knob. Only the symbol of
the selected material will be displayed (the others
will disappear), and one of the available wire
diameters (in the diameter group) will start
flashing. Similarly as before, by turning the lower
knob in any direction, set the required wire
diameter.
Confirm the diameter and move to the
group of shielding gases by briefly pressing
the lower knob.
Then select the required shielding gas with the lower knob by turning it in any direction. A short
press of the lower knob confirms the selection and exits the menu.
After leaving the synergic mode menu, the welder should be adjusted depending on the thickness of the
welded element - it is used by the upper knob.