Shutdown and Cleaning
312082B
19
Power Flush
Power flushing is a faster method of flushing. It can only
be used after spraying water-based coatings.
1.
Relieve pressure, page 7.
2.
If you used a spray gun, remove tip and guard
assembly from gun and place in flushing fluid.
If you used a roller, leave roller assembly attached
to gun.
3.
Place waste and paint pails
side by side.
4.
Lift Suction tube and prime tube from paint pail. Let
them drain into paint for a while.
5.
Place suction and prime tube in waste pail.
6.
Screw power flush attachment to
garden hose. Close valve.
7.
Turn on water. Open valve.
Rinse paint off Suction tube,
prime tube and inlet screen.
8.
Turn lever to close power flush
attachment.
9.
Unscrew inlet screen from
Suction tube. Place inlet screen
in waste pail.
10. Connect garden hose to Suction tube
with Power Flush attachment. Leave
prime tube in waste pail.
11. Open lever on Power Flush
attachment.
12. Turn AllControl to PRIME/CLEAN
PUMP.
13. Circulate water through sprayer, into waste pail for
20 seconds.
14. Turn AllControl to OFF.
ti9726a
ti9413a
ti9727a
TIA
TIA
TIA
OPEN
ti9169a
ti9168a