Operation
10
313034G
Operation
Trigger Lock
Always engage the trigger lock when you stop spraying
to prevent the gun from being triggered accidentally by
hand or if dropped or bumped.
Pressure Relief Procedure
Follow this Pressure Relief Procedure whenever you
stop spraying and before cleaning, checking, servicing,
or transporting equipment.
1.
Turn power switch OFF and unplug
power cord.
2.
Turn Prime/Spray valve to
PRIME to relieve pressure.
3.
Hold gun firmly to side of pail.
Trigger the gun to relieve
pressure.
4.
Engage trigger lock.
NOTE: Leave Prime/Spray valve in the PRIME
position until you are ready to spray again.
If you suspect the spray tip or hose is clogged or that
pressure has not been fully relieved after following the
steps above, VERY SLOWLY loosen tip guard retaining
nut or hose end coupling to relieve pressure gradually,
then loosen completely. Clear hose or tip obstruction.
Read Unclogging Spray Tip, page 14.
NOTE: To select function, align symbol on pressure control knob with setting indicator on sprayer.
ti8908a
Trigger Locked
Trigger Unlocked
ti8909a
ti2810a
ti9346a
ti11986a
ti8908a
Pressure Control Knob Settings
High Pressure
Spray
Low Pressure
Spray
Prime/
Clean
Rolling
ti5597a
Summary of Contents for 24N808