©2013 Magnum Energy, Inc.
2
2.0 Installation
2.0 Installation
Review this section and the Important Product Safety Instructions on page ii
before proceeding with the installation of your remote.
WARNING:
Installations should be performed by quali
fi
ed per-
sonnel, such as a licensed or certi
fi
ed electrician. The installer
determines which safety codes apply and ensures all applicable
installation requirements are followed. Applicable installation codes
vary depending on the speci
fi
c location and application.
CAUTION:
When connecting battery power to the inverter, all
battery negative connections must be connected prior to the bat-
tery positive connections. When removing battery power from the
inverter, the battery positive should be removed before any battery
negative connections are disconnected. This prevents any com-
munication chips/lines from becoming the DC return path to the
battery—causing permanent damage to all connected accessories.
Summation:
Ensure all battery negative circuits are always con-
nected before connecting or disconnecting battery positive.
2.1
Pre-Installation
Before proceeding, read the entire Installation section to determine how best
to install your ME-RC remote. The more thorough you plan in the beginning,
the better your inverter needs will be met.
2.1.1 Installation Guidelines
•
Before connecting any wires, determine the remote’s cable route through-
out the home or vehicle/boat, both to and from the inverter.
•
Always check for existing electrical, plumbing, or other areas of potential
damage BEFORE drilling or cutting into walls to mount the remote.
•
Make sure all wires have a smooth bend radius and do not become kinked.
•
If installing this remote in a boat, RV, or truck ensure the conductors
passing through walls, bulkheads, or other structural members are pro-
tected. This minimizes insulation damage (such as cha
fi
ng) which can
be caused by vibration or constant rubbing.
2.1.2 Unpacking and Inspection
Carefully remove the ME-RC remote from its shipping container and inspect
all contents. Verify the following items are included:
•
The ME-RC remote
•
50’ remote cable
•
Four #8 x 3/4 Phillips screws
•
ME-RC Owner’s Manual
If items appear to be missing or damaged, contact your authorized Magnum
Energy dealer or Magnum Energy, Inc. Save your proof-of-purchase as a
record of your ownership; it is needed if the unit should require in-warranty
service.
2.1.3 Tools Required
Installing the remote control is simple and requires the following tools:
• Phillips screwdriver
• Level • Drill
• Cut-out tool (knife/saw)
• Pencil • Drill Bit (7/64”)