6.0 Troubleshooting
6.0 ME-RC Remote Troubleshooting
The remote may not be functioning correctly, use the following table to help
fi
nd a solution.
Symptom
Possible Cause
Solution
Display shows
unrecognizable
letters or
symbols
Static electricity
may have been
discharged into the
LCD display.
Refresh display
: Press and
hold the SELECT button for 10
seconds.
Display shows
“
fatal error
”
or “
illegal
address
”
The remote’s internal
data addressing was
unrecognizable.
Reset remote
: Disconnect
remote communications cable
from inverter for 5 seconds and
reconnect (see Figure 2-2).
LCD text
display is
locked-up,
pressing any
button has
no response
– may show
“
revision
” or
“
connecting
”
RJ11 connections on
communication cable
are not making a
good connection.
Reset remote
: 1) Disconnect
remote cable from inverter for
5 seconds and reconnect; 2)
Check RJ11 cable connection on
back of remote (see Fig. 2-2).
Important: Ensure the RJ11
connector is pushed into
the correct port. You should
feel/hear “click” when the
connection is made.
Remote not getting
suf
fi
cient power from
inverter.
Ensure inverter batteries are
connected and inverter is
operating correctly. Inverter
should be able to invert and
power AC loads from batteries
(ensure no AC power is
connected to the inverter AC
inputs).
LEDs and
backlight are
off
Remote may be in
the Power Saver
mode.
Press any button to reactivate
the remote (or turn Power
Saver mode
OFF
).
Remote is
nonfunctional
(no lights, no
text on LCD
display, and no
response when
pressing any
button)
Communication
cable bad or not
correctly connected
to REMOTE port on
inverter.
Check communications cable
from inverter to remote;
ensure: 1) it is connected to
the REMOTE port, 2) the correct
communications cable is used
(a 4-conductor telephone
cable may be substituted to
determine if cable is good).
Inverter is not
connected to
batteries.
Ensure inverter batteries are
connected and the inverter
is operating correctly without
any AC power connected (can
invert and power AC loads from
batteries).
Table 6-1, Remote Control Troubleshooting Guide