Setup
the generator immediately once the temperature rises to this
setting. The temperature start setting is adjustable from 65°F-85°F
(18°C-29°C). If this feature is not needed, ensure the adjustment
knob is turned fully counterclockwise to the
OFF
position.
Why would I use the temperature start feature?
For RV users,
you can set the AC to turn on (with power provided by generator)
and leave the RV. The generator will automatically start when the
temperature rises to your AGS temperature start setting, providing
power to the air conditioner; thereby, turning it on. This allows you
to leave pets and precious items in your coach while dry camping in
hot weather; knowing your RV will stay cool and comfortable—plus,
while the generator is on, the house batteries are being charged.
START VOLTS DC:
This setting allows you to enable and set a
battery voltage value that causes the generator to automatically
start. When the battery voltage decreases to or below this setting
for two continuous minutes, the generator automatically starts
and runs based on the
RUN TIME HOURS
setting. The voltage start
setting is adjustable from 10-12 VDC (12 VDC jumper), 20-24 VDC
(for 24 VDC jumper), or 40-48 VDC (48 VDC jumper). If the DC
voltage start feature is not needed, turn the adjustment knob fully
counterclockwise to the
OFF
position.
Info:
For 24 VDC applications, double the value indicated on
the cover (i.e., 11 VDC = 22 VDC) and for 48 VDC applications,
multiply the indicated value by four (i.e., 11 VDC = 44 VDC).
CLOCK AM/PM:
This setting is used to set the internal clock of the
AGS. The internal clock must be set to the correct time in order for the
Quiet Time feature to function appropriately. If the Quiet Time feature
is not used, this clock setting is not required to be adjusted.
To set or change the clock, ensure the current time of day is between
the hours of 8 AM and 4 PM; then, slowly rotate the knob marked
CLOCK AM/PM
clockwise to increase the time or counterclockwise to
decrease the time. Once set, the clock will continue to keep time.
However, the clock must be reset if the controller loses power, or
when you change time zones.
QUIET TIME PM/AM:
This setting is used to prevent the generator
from starting during speci
fi
c hours of the evening (PM) and early
morning (AM). It is adjustable for
fi
ve pre-selected time ranges.
To set Quiet Time, turn the dial either counterclockwise or clockwise
to the hours required: 9-7 (9 PM to 7 AM), 9-8 (9 PM to 8 AM), 9-9
(9 PM to 9 AM), 10-8 (10 PM to 8 AM), or 11-8 (11 PM to 8 AM).
The program only needs to be set once. If the Quiet Time feature is
not needed, turn the dial fully counterclockwise to the
OFF
position.
Info:
If the generator is running when the Quiet Time evening
hour (PM) is reached, it automatically stops and does not
automatically start until after the Quiet Time morning hour