50
58-603 Pulsar
®
Model R86 Radar Transmitter
Priority
Indicator Name
Default
Category
Explanation
Remedy
18
Spare Indicator 5
OK
Reserved for future use.
19
Initializing
Function
Check
Distance measurement is inaccurate
while internal filters are settling.
Standard start-up message. Wait for
up to 10 seconds.
20
Config Changed
Function
Check
A parameter has been modified from
the User Interface.
If desired, reset Config Changed
indicator in ADVANCED CONFIG
menu.
21
Spare Indicator 6
OK
Reserved for future use.
22
Ramp Slope Error
Failure
Internal signal timing out of limits
causing inaccurate distance
measurement.
Check accuracy of Level reading.
Replace transmitter electronics.
Contact MAGNETROL Technical Support.
23
High Elec Temp
Out of Spec
Electronics too hot. May compromise
level measurement or damage
instrument.
Shield transmitter from heat source or
increase air circulation. Locate
transmitter remotely in a cooler area.
24
Low Elec Temp
Out of Spec
Electronics too cold. May compromise
level measurement or damage
instrument.
Insulate transmitter.
Locate transmitter remotely in a
warmer area.
25
Calibration Req’d
Out of Spec
Factory calibration has been lost.
Measurement accuracy may be
diminished.
Return transmitter to factory for
recalibration.
26
Echo Reject
Invalid
Out of Spec
Echo Rejection inoperative. May report
erroneous Level readings. Upr Echo
may be lost.
Save a fresh Echo Rejection Curve.
27
Spare Indicator 7
OK
Reserved for future use.
28
Inferred Level
Out of Spec
Level inferred to have entered Blocking
Region if echo lost within Max Distance
Jump of Top or Bottom Blocking
Region.
Verify level reading; if incorrect, check
configuration.
29
Adjust Analog Out
Out of Spec Loop current is inaccurate.
Perform Adjust Analog Output
maintenance procedure.
30
Low Supply
Voltage
Out of Spec
Loop current may be incorrect at higher
values. Analog output is inaccurate.
Verify loop resistance.
Replace loop power supply.
31
Spare Indicator 8
OK
Reserved for future use.
32
Max Jump Exceeded
Maintenance
Required
Transmitter has jumped to an echo at
location that exceeds “Max Level
Jump” from previous echo location.
Check settings:
Dielectric Range
Sensitivity
View Echo Curve.
33
Low Echo Margin
Maintenance
Required
Signal Margin is less than allowable
minimum.
Check settings:
Dielectric Range
Sensitivity
View Echo Curve.
34
High Surface
Velocity
Maintenance
Required
Measured Surface Velocity greater than
Max Surface Velocity derived from
configured Rate of Change.
Confirm actual rate of change. Adjust
rate of change setting, if needed.
35
Spare Indicator 9
OK
Reserved for future use.
36
Spare Indicator 10
OK
Reserved for future use.
37
Sequence Record
OK
A Sequence Record number has been
stored in Event Log.
If desired, report Sequence Record
number to factory.