Barrier MHTM
TM
MicroDrive Access and Parking
Assembly and installation
62
8.7 Assemble
housing
The barrier housing is attached by 4 foundation anchors via 2
attachment profiles. The attachment profiles are included in
delivery. You can order a mounting set consisting of foundation
anchor, washers, spring rings and hexagon nuts from MAGNETIC
Autocontrol GmbH as accessories.
Requirements
mounting material
If you are using your own mounting material, it must meet the
following requirements:
4 foundation anchors:
Features: suitable for concrete C35/45 XD3 XF2
Material: electrogalvanised
Size: M8 x 160
Tensile strength: at least 8.8 kN
Foundation anchors that are optionally available from
MAGNETIC achieve the tensile strength of 8.8 kN at a
drilling depth of 80 mm.
4 washers DIN 9021 d13, zinc-plated
4 washers DIN 9021 d8,4, zinc-plated
4 spring washers DIN 128 A8, zinc-plated
4 hexagon nuts DIN 934 M8, zinc-plated.
8
1
2
5
6
7
4
3
9
Mag00205
Fig. 22: Assemble housing
1 Barrier
housing
2 Nut
3 Spring
washer
4 Washer
d8,4
5 Washer
d13
6 Mounting
profile
7 Foundation
anchor
8 Foundation
9 Silicon
joint