Intelli-Protect User Manual
April 2023
2.6 Laser Alignment Instructions
1.
The factory default setting for the laser pointer in the menu is “Auto.”
–
If the sensor does not detect a target, the laser pointer flashes at a frequency of approximately
1 Hz.
–
Perform the alignment at the maximum possible distance.
2.
Align the sensor so that the red laser dot is as close to center of reflector as possible.
–
As soon as the distance measurement device has detected a target, the laser pointer flashes for
an additional two minutes before deactivating automatically.
–
Run the crane to test and verify the laser dot remains on the reflector for the entire span of
operation.
2.7 Fixed Location Installation: Windmill Switches
Intelli-Protect
®
Fixed Location systems utilize four-pole limit switches with trip arms mounted at desired
slowdown, stop, and protected zone boundaries.
Trip arms should be mechanically mounted according to the following guidelines to achieve the best
results.
Figure 2-7: Trigger Mounting