Intelli-Protect User Manual
April 2023
1.4 Light Stack
Three-Segment light stack with horn
NOTE:
If the panel bypass key switch is switched to disable the No-Fly Zone protection, the red
light will flash continuously until protection has been re-enabled by the bypass key switch. When
Bypass is initiated the Horn will turn on for 10 seconds and off for 10 seconds (this will happen
twice). When the Normal Operation is initiated the Horn will sound for 2 seconds then shut off.
Light Indicators
Intelli-Protect
®
Color
Industry Standard
No-Fly Zone
Green
Safe/Normal
Power on, PLC running - Solid
Amber
Warning/Abnormal
Within Stop Zone - Solid
Within Slowdown Zone - Flashing
Red
Danger/Fault
Within Restricted Zone - Solid
Bypass - Flashing with horn sound
No Zones Configured – Flashing
with no horn