IMPULSE®•G+ & VG+ Series 3 to Series 4 Transition Guide August 2011
Page 47 of 54
Magnetek, Inc.
Product Transition Guide
IMPULSE
®
•G+ & VG+ Series 4
Terminal M5-M6
Sel
H2-03
G+: F
VG+: 78
H2-03
Determined by X-
Press
Programming
Range: 0 through
FF (See Instruction
Manual for
complete list)
Range: 0 through
148 (See
Instruction Manual
for complete list)
Term A1 LvL SeL
H3-01
0
H3-01
0
0: 0 VDC to 10
VDC
0: 0VDC to 10V
1: -10 VDC to +10
VDC
1: -10V to +10V
Terminal A1 Gain
H3-02
100%
H3-03
100.0%
--
Terminal 13 Bias
H3-03
0%
H3-04
0.0%
--
Terminal A1 Bias
H3-04
0
H3-05
0
0: 0 VDC to 10
VDC
0: 0 VDC to 10V
1: -10 VDC to +10
VDC
1: -10V to +10V
Terminal A3 Sel
H3-05
1F
H3-06
1F
Range: 1 through
1F (See instruction
manual for
complete list)
Range: 1 through
31 (See instruction
manual for a
complete list)
Terminal A3 Gain
H3-06
100.0%
H3-07
100.0%
--
Terminal A3 Bias
H3-07
0.0%
H3-08
0.0%
--
Term A2 Signal
H3-08
2
H3-09
2
0: 0 to +10 VDC
*(Call
Electromotive
Systems first to
modify control
board).
0: 0 to +10V
1: -10 to +10 VDC
*(Call
Electromotive
Systems first to
modify control
board).
1: -10 to +10V
2: 4 to 20mA
2: 4 to 20mA
--
3: 0 to 20mA
Terminal A2 Sel
H3-09
1F
H3-10
0
Range: 0 through
1F (See instruction
manual for
complete list)
Range: 0 through
31 (See instruction
manual for complete
list)
Terminal A2 Gain
H3-10
100.0%
H3-11
100.0%
--
Terminal A2 Bias
H3-11
0.0%
H3-12
0.0%
--
Filter Avg Time
H3-12
0.00 sec
H3-13
0.03 sec
--
Terminal FM Sel
H4-01
2
H4-01
102
Range: 0 though
50 (See Instruction
Manual for
complete list)
Range: 0 through
999 (See
Instruction Manual
for complete list)
Terminal FM Gain
H4-02
100.0%
H4-02
100.0%
--
Terminal FM Bias
H4-03
0.0
H4-03
0.0%
--
Terminal AM Sel
H4-04
3
H4-04
103
--
Terminal AM Gain
H4-05
50.0%
H4-05
50.0%
--
Terminal AM Bias
H4-06
0.0%
H4-06
0.0%
--
Parameter
Name
Series 3
Series 4
Comments
No.
Default
No.
Default
Series 3
Series 4