C
Co
on
ns
stta
an
ntt N
No
o.. o
off A
Au
utto
o--rre
es
stta
arrtt
Range: 0 - 10
n
n 6
6 0
0
A
Atttte
em
mp
ptts
s
Factory Setting: 0
The GPD 205 can be programmed for auto-restart to automatically reset a fault which
occurs during operation. Auto-restart operation will use the number of restart
attempts set in this constant, up to the maximum of ten. When set to “ 0 ”, no auto-
restart will be attempted.
• Only the following faults can be automatically reset:
o
o C
C : Overcurrent
o
o u
u : Overvoltage (OV)
• The number of restart attempts available will be reset to the constant n60 setting
when:
1.
10 minutes have elapsed without a fault occurring.
2.
An external Fault Reset push button is pressed (or the R
RE
ES
SE
ET
T
key of the Digital Operator is pressed).
3.
The input power to the GPD 205 is turned OFF long enough for
the drive to re-initialize itself when power is turned back ON.
C
Co
on
ns
stta
an
ntt O
Op
pe
erra
atto
orr ““S
Stto
op
p”” K
Ke
ey
y
Range: 0, 1
n
n 6
6 1
1
S
Se
elle
ec
cttiio
on
n
Factory Setting: 0
This function is used to enable/disable the “Stop” key on the digital keypad. When
set to “ 0 ”, the key is enabled and the drive can be stopped by pressing the “Stop”
key. When set to “ 1 ”, the key is disabled and the end user will not be able to stop
the operation of the drive by pressing the “Stop” key.
C
Co
on
ns
stta
an
ntt S
Slliip
p C
Co
om
mp
pe
en
ns
sa
attiio
on
n
Range: 0.0 - 25.5 (sec)
n
n 6
6 2
2
D
De
ella
ay
y T
Tiim
me
err
Factory Setting: 2.0
This function is used as a stabilization factor when the application has varying loads.
54
for more: efesotomasyon - Yaskawa drive