![background image](http://html1.mh-extra.com/html/magnetek/flex-m/flex-m_manual_3580922022.webp)
Flex M Engineered Receiver Instruction Manual
May 2019
Page 22 of 50
Figure 14. GEN2 Power Supply Module Detail View
Figure 15. GEN2 Power Supply VAC Wiring
Figure 16. GEN2 Power Supply VDC Wiring
NOTES:
1. Although the power module has built-in protection, Magnetek strongly recommends the use of
external fuses and circuit disconnects for all Flex modules.
2. The built-in fuse is user serviceable and can be replaced if blown. To check the fuse, remove the
power module from the din rail as described in Section 3.9. Remove the top cover to reveal FH1,
the cylindrical fuse holder. Using a flat-bladed screwdriver, turn the cap a quarter turn counter-
clockwise, and remove the cap. Use a multimeter to check for continuity across the fuse. If the
fuse is blown, replace with a fuse matching the installed specifications.
3. The total system current consumption should not exceed the maximum output supply current of
the power supply module. If additional supply current is required, contact the factory for a custom
solution.