![background image](http://html1.mh-extra.com/html/magnetek/flex-8ex-a-b/flex-8ex-a-b_instruction-manual_693936032.webp)
Flex 8EX A/B System Instruction Manual
June 2010
30 of 42
JP
7
JP
1
JP
5
JP
3
JP
2
JP
4
JP
6
5. Jumper
Settings
Jumper settings are applied to functions such as mainline-disconnect time, Start function,
transmitter push button layout, system information (serial number/ID code) programming and
system testing. The jumpers #1- #7 are located on the decoder module above the four (4) dip-
switches (refer to Fig.16 below).
(Fig. 16)
▇
Manufacture preset
Jumper Settings
Function
JP1
(Blank)
JP2
(Blank)
Receiver MAIN remains closed until the transmitter power is turned
off or emergency stop command is initiated.
JP1
(Inserted)
JP2
(Blank)
Receiver MAIN opens after 5 minutes of system inactivity.
JP1
(Blank)
JP2
(Inserted)
Receiver MAIN opens after 30 minutes of system inactivity.
JP1
(Inserted)
JP2
(Inserted)
Receiver MAIN opens after 60 minutes of system inactivity.
JP3
(Blank)
Press any push button on the transmitter to activate the receiver MAIN at
system startup, after E-stop reset, and after system inactivity
(refer to JP1 & JP2 settings above).
JP3
(Inserted)
Rotate the power key switch to “START” position to activate the receiver
MAIN at system startup, after E-stop reset, and after system inactivity
(refer to JP1 & JP2 settings above).
JP4
(Blank)
JP5
(Blank)
Standard right-to-left push button configuration for all models.
JP4
(Inserted)
JP5
(Blank)
In-line push button configuration (top to bottom) for Flex 8ES/EX.
JP4
(Blank)
JP5
(Inserted)
In-line push button configuration (top to bottom) for Flex 12ES/EX.
JP4
(Inserted)
JP5
(Inserted)
In-line push button configuration (top to bottom) for Flex 4ES/EX.
JP6
(Blank)
Program system serial number/ID code and channel from decoder module
to I-CHIP.
JP6
(Inserted)
Program system serial number/ID code and channel from I-CHIP
to decoder module.