4.1.5
Transmitter Inactivity Timer Settings
Set how long the transmitter enters the sleep mode when not in use (pushbutton not
pressed). When transmitter goes into sleep mode the receiver MAIN relays are
deactivated.
4.1.6
Transmitter Output Power Settings
1mW offers the shortest operating range with lowest battery consumption while 10mW
offers the longest operating range with highest battery consumption. Default is 2mW.
4.1.7
Infrared Programming
Other custom functions and settings not listed in this manual
can be programmed via the infrared IR programmer unit, such
as the system serial number, frequency range, relay output
status feedback, new and updated functions, and many others.
Please contact Magnetek field service for more details.
4.1.8
Pushbutton Function Settings
1. Rotate the power switch key to OFF ( 0 ) position.
2. With the STOP button elevated, press and hold PB3 and PB4 at the same time.
3. Rotate the power switch key to ON ( I ) position.
4. Release PB3 and PB4 at the same time. The system will enter Pushbutton Function
mode.
Dipswitch
Settings
Time
Dipswitch
Settings
Time
1
xxx
000
xxxx
1 minute
5
xxx
100
xxxx
10 minutes
2
xxx
001
xxxx
20 seconds
6
xxx
101
xxxx
30 minutes
3
xxx
010
xxxx
3 minutes
7
xxx
110
xxxx
60 minutes
4
xxx
011
xxxx
5 minutes
8
xxx
111
xxxx
Constant On (sleep
mode disabled)
Dipswitch
Settings
Output Power
Dipswitch
Settings
Output Power
1
000
xxxxxxx
1mW
5
100
xxxxxxx
5mW
2
001
xxxxxxx
2mW
6
101
xxxxxxx
6mW
3
010
xxxxxxx
3mW
7
110
xxxxxxx
8mW
4
011
xxxxxxx
4mW
8
111
xxxxxxx
10mW