Flex 4Base® CE Instruction Manual
January 2017
Page 28 of 41
1
3
2
4
7
5 6
8
4.2.3.2 Non-Interlocked Pushbutton Pair
Non-interlocked setting allows the pushbutton pair(s) be pressed simultaneously. It usually
applies to the equipment’s auxiliary functions such as lights, horns, or buzzers. Each
dipswitch on the RF/decoder board corresponds to a pushbutton pair. Only the first seven
dipswitch positions are used (counting from left to right); the eighth dipswitch position (far
right) is not used.
Function
Code
Dip
Position
#1
Dip Position
#2 ~ #4 (left button)
&
#5 ~ #7 (right button)
Function Description
A
1 000 Normal (momentary) contact
B
1 001
Toggled (latching) contact
C
1 100
Start function - For added
safety, you must first press and hold the
START button and then press the
intended pushbutton to activate the
output relay.
D
1 110
Pitch & Catch
E
1 111
2 steps with Closed/Closed relay action
Example #1: Left button (set to function code A) / right button (set to function code B)
→
1
000 001
Example #2: Left button (set to function code C) / right button (set to function code D)
→
1