21
www.magmaweld.com
USER MANUAL | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
EN
monoTIG 160i / monoTIG 200i
MAINTENANCE AND SERVICE
• Maintenance and repairs to the machine must be carried out by a qualified personnel. Our company will not be
responsible for any accidents that may occur by unauthorized interventions.
• Parts that will be used during repair can be obtained from our authorized services. The use of original spare parts
will extend the life of your machine and prevent performance losses.
• Always contact the manufacturer or an authorized service designated by the manufacturer.
• Never make interventions yourself. In this case the macufacturer warranty is no langer valid.
• Always comply with the applicable safety regulations during maintenance and repair.
• Before performing any work on the machine for repair, disconnect the machine’s power plug from the power
supply and wait for 10 seconds for the capacitors to discharge.
4.1 Maintenance
Daily Maintenance
• Check your torch, clamps and cables. Pay attention to the connections and the durableness
of the parts. Replace the damaged/defective parts with the new ones. Do not ever make
additions to/repair the cables.
• Ensure adequate space for ventilation.
• The consumables on the TIG torch must be cleaned regularly. Should be replaced if
necessary. It should be ensured that these materials are original products for a long-term
use.
• Before starting welding, check the gas flow rate from the tip of the torch with a flow meter.
If the gas flow is high or low, bring it to the appropriate level for the welding process.
Every 6 Months
NOTE: The above mentioned periods are the maximum ones that should be applied if no problems
are encountered in your device. Depending on the work load and contamination of your work
environment, you can repeat the above processes more frequently.
Never operate the machine when covers are open.
• Do not remove the warning labels on the device. Replace the worn/torn labels with the
new ones. Labels can be obtained from the authorized service.
• Clean and tighten fasteners such as bolts and nuts.
• Check the electrode clamp and grounding clamp cables.
• Open the side covers of the machine and clean with low pressure dry air. Do not
apply compressed air to electronic components at close distance.
• Check the socket to which the power supply plug of the machine is connected. If
there is any looseness in the power cable connection points of the socket, remove
such looseness. If there is an arc or expansion in the socket slots, replace them with
new ones.
• Check the power supply plug of the machine. If there is any looseness in the power
cable connection points in the electricity plug, remove such looseness. If there is an
arc or deformation at the ends of the plug, replace it with a new one.
or
Maintenance and Service
Summary of Contents for monoTIG 160i
Page 29: ...29 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i...
Page 31: ...31 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i n...
Page 32: ...32 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i...
Page 35: ...35 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i IMF...
Page 46: ...46 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i 3 3 3...
Page 47: ...47 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i 10 4 1 TIG 6...
Page 48: ...48 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i 1 4 2 4 3 E01...
Page 49: ...49 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i E02 E03...
Page 50: ...50 www magmaweld com USER MANUAL KULLANIM KILAVUZU RU monoTIG 160i monoTIG 200i 5 1...
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......