1-9-4
TD603EA
10.Set the color analyzer to the CHROMA mode and
after zero point calibration, bring the optical recep-
tor to the center on the tube surface (CRT).
11.Choose CUT OFF/DRIVE mode then press "4" but-
ton on the service remote control unit for Red adjust-
ment. Press "5" button on the service remote control
unit for Blue adjustment.
12.In each color mode, press "CH
o
/
p
" buttons to
adjust the values of color.
13.Adjust Red and Blue color so that the temperature
becomes 9200K (x : 286 / y : 294) ±3%.
14.At this time, re-check that horizontal line is white. If
not, re-adjust Cut-off Adjustment until the horizon-
tal line becomes pure white.
15.Turn the power off and on again.
9. H. Size Adjustment
Purpose:
To obtain correct size of screen image.
Symptom of Misadjustment:
Size of screen image
may not be properly displayed.
Note:
VR531 --- H.V. CBA
1. Input monoscope pattern.
2. Adjust VR531 so that the monoscope pattern is
90+1%/-5% of the display size and the circle is
round.
10. H. Pincushion Adjustment
Purpose:
To obtain straight line on the screen.
Symptom of Misadjustment:
Straight line image may
not be properly displayed.
Note:
VR530 --- H.V. CBA
1. Input crosshatch pattern.
2. Adjust VR530 so that the line of the crosshatch pat-
tern becomes straight.
11. Sub-Brightness Adjustment
Purpose:
To get proper brightness.
Symptom of Misadjustment:
If Sub-Brightness is
incorrect, proper brightness cannot be obtained by
adjusting the Brightness Control.
Note:
SYMPTE Setup level --- 7.5 IRE
1. Enter the Service Mode. (See page 1-9-1.)
Then input SYMPTE signal from RF input.
2. Press "PICTURE" button. (Press "PICTURE" but-
ton then display will change B R T, C N T, T N T, V-
T and SHP). Select BRT and press "CH
o
/
p
" but-
tons so that the bar is just visible (See above fig-
ure).
3. Turn the power off and on again.
12. Focus Adjustment
Purpose:
Set the optimum Focus.
Symptom of Misadjustment:
If Focus Adjustment is
incorrect, blurred images are shown on the display.
Notes:
Focus VR (FBT) --- H.V. CBA
FBT= Fly Back Transformer
1. Operate the unit more than 30 minutes.
2. Face the unit to the East and degauss the CRT
using a degaussing coil.
3. Input the monoscope pattern.
4. Adjust the Focus Control on the FBT to obtain a
clear picture.
Adj. Point
Input
VR531
Monoscope
M. EQ.
Spec.
Pattern Generator
90+1%/-5%
Adj. Point
Input
VR530
Crosshatch
M. EQ.
Spec.
Pattern Generator
See below
Adj. Point
Input
CH
o
/
p
buttons
SYMPTE 7.5IRE
M. EQ.
Spec.
Pattern Generator
See below
Figure
Adj. Point
Input
Focus Control
Monoscope
M. EQ.
Spec.
Pattern Generator
See below.
Black
White
This bar
just
visible